c/kWh
Energy rating (cooling)
1
Heating: 0
Annual electricity use
6,700 kWh
Estimated running cost
$2,144 / year
$179 / month Β· $21,440 over 10 years
Capacity
49.1 kW cooling
51.8 kW heating

3% less electricity than the median of 5 comparable 50 kW reverse cycle ducted split system registrations (6,902 kWh a year) in the mixed zone. Uses less than 80% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 12% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Actron Air CAY500T running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,474$1,432$14,317
Mixed zone 6,700$2,144$21,440
Hot zone 19,299$6,176$61,757

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners similar to the Actron Air CAY500T

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Temperzone OSA570RKTB/ISD570KB55 kW heating54 kW cooling7,291 kWh/yr1.5$2,333
Temperzone OSA570RKTB/ISD570KB-P53.4 kW heating55 kW cooling6,981 kWh/yr1.5$2,234

Other Actron Air models of similar capacity

ModelStarsEst. cost / yrCompare
Actron Air CAY500T / ELY500T51.9 kW heating48.6 kW cooling6,808 kWh/yr1$2,179

Compare CAY500T / EVY500T with another model

Actron Air CAY500T specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
49.10 kW
Cooling power input
15.34 kW
Rated heating capacity (7 Β°C)
51.80 kW
Heating power input
15.36 kW
EER, full load (tested)
3.11
COP, full load (tested)
3.28
Rated AEER
3.14
Rated ACOP
3.31
Standby power (PIA)
92.0 W
Compressor
Variable speed
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Australia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Actron Air CAY500T zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––10,042–
Coldresidential1.00.04,474–
Mixedcommercial––12,338–
Mixedresidential1.00.06,700–
Hotcommercial––26,431–
Hotresidential1.50.019,299–
Part-load test points (1 values)
c__low_temp_have_full_cap_results
No

Australian GEMS registration details

Registration number
AAC9588
GEMS registration id
174062
Status
approved, available (self-reported)
Registration expires
18 April 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
Simulation
MEPS
2019
Product class
Class 12

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.