c/kWh
Energy rating (cooling)
2.5
Heating: 2
Annual electricity use
3,076 kWh
1,261 cooling + 1,815 heating
Estimated running cost
$984 / year
$82 / month Β· $9,843 over 10 years
Capacity
13 kW cooling
12.8 kW heating

3% less electricity than the median of 140 comparable 12.5 kW reverse cycle ducted split system registrations (3,178 kWh a year) in the mixed zone. Uses less than 57% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 34% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Actron Air CRV13BT running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,754$1,841$18,413
Mixed zone 3,076$984$9,843
Hot zone 3,883$1,243$12,426

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 13 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Panasonic U-125PZ3R8 / S-1014PF3E12.1 kW heating12.1 kW cooling1,681 kWh/yr1.5$538
Brivis AONSR13B1/AINHU13B113.8 kW heating12 kW cooling2,209 kWh/yr4$707
Brivis AONSR15B1/AINHU15B115.7 kW heating13.6 kW cooling2,497 kWh/yr5$799
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling2,556 kWh/yr3.5$818
Rinnai DONSR13B1/DINLR13B113 kW heating12.5 kW cooling2,559 kWh/yr3.5$819

Air conditioners similar to the Actron Air CRV13BT

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Haier 1U140S2SP5FA / AD140S2SM7FA15 kW heating13 kW cooling3,854 kWh/yr2$1,233
Fujitsu AOTG54LBTB/ARTG54LHTDP16 kW heating13 kW cooling3,665 kWh/yr2.5$1,173
Hisense AUW-125U4RH1/AUD-125UX4RSH115.5 kW heating13 kW cooling3,223 kWh/yr3$1,031
Fujitsu AOTH54KBTA/ARTH54KMTAP15 kW heating13 kW cooling3,527 kWh/yr2.5$1,129
Rinnai DONSR12Z72/DINLR12Z7215 kW heating13 kW cooling3,036 kWh/yr3$972
Kaden KD4215 kW heating13 kW cooling3,551 kWh/yr2$1,136
Temperzone OSAT 130RLSFH / ISDT 130LY15.5 kW heating13 kW cooling3,354 kWh/yr2.5$1,073
Braemar KCHV160D1B/KGHV200A1T17 kW heating13.2 kW cooling3,628 kWh/yr2.5$1,161

Compare CRV13BT / EVV13BS with another model

Actron Air CRV13BT specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
13.00 kW
Cooling power input
3.77 kW
Rated heating capacity (7 Β°C)
12.85 kW
Heating power input
3.08 kW
EER, full load (tested)
3.40
COP, full load (tested)
4.08
Rated AEER
3.39
Rated ACOP
4.09
Standby power (PIA)
19.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Australia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Actron Air CRV13BT zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,4431,629
Coldresidential2.51.58164,938
Mixedcommercial––1,969824
Mixedresidential2.52.01,2611,815
Hotcommercial––4,518194
Hotresidential3.02.53,588295
Part-load test points (20 values)
h__h2_ext_cap_power_rated
3252 W
c__t1_half_cap_power_rated
1605 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1406 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
9948 W
h__h1_half_cap_heat_cap_rated
6652 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
3449.436 W
c__low_temp_half_cap_power_rated
1219 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
6227 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_full_cap_cooling_cap_rated
14001 W
c__low_temp_half_cap_cooling_cap_rated
6456 W

Other model numbers on registration AAC8460

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC8460
GEMS registration id
162606
Status
approved, available (self-reported)
Registration expires
19 September 2029
Registered for sale in
Australia, New Zealand
Family
CRV13BT / EVV13BS
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.