Australia Β· costs in AUD

Reverse cycle split system air conditioner
Actron Air CRV25BT / EVV25BS Air Conditioner
Actron Air CRV25BT / EVV25BS is a 25 kW reverse cycle ducted split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC8793).
- Energy rating (cooling)
- 2.5
- Heating: 2.5
- Annual electricity use
- 5,912 kWh
- 2,369 cooling + 3,543 heating
- Estimated running cost
- $1,892 / year
- $158 / month Β· $18,918 over 10 years
- Capacity
- 25 kW cooling
- 26 kW heating
18% less electricity than the median of 17 comparable 25 kW reverse cycle ducted split system registrations (7,214 kWh a year) in the mixed zone. Uses less than 88% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 14% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Actron Air CRV25BT running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 11,248 | $3,599 | $35,994 |
| Mixed zone | 5,912 | $1,892 | $18,918 |
| Hot zone | 7,453 | $2,385 | $23,850 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 25 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Actron Air CRV22BT / EVV22BS23 kW heating22 kW cooling5,232 kWh/yr | 2.5 | $1,674 | |
| Actron Air CRV22BT / EAA22BS & EFV22BS23 kW heating22 kW cooling5,232 kWh/yr | 2.5 | $1,674 | |
| Panasonic U-224PZH3R8 / S-224PE4R25 kW heating22.4 kW cooling5,726 kWh/yr | 2.5 | $1,832 |
Air conditioners similar to the Actron Air CRV25BT
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Fujitsu AOTA90LALT/ARTC90LATU28 kW heating25 kW cooling7,818 kWh/yr | 1.5 | $2,502 | |
| Mitsubishi Electric PUZ-ZM250YKA-A / PEA-M250LAA28 kW heating24.5 kW cooling6,534 kWh/yr | 2 | $2,091 | |
| Braemar SCHV24D3S/SDHV24D1S26 kW heating24 kW cooling7,557 kWh/yr | 1.5 | $2,418 | |
| Daikin RZYQ10TAY1 / FDYQ250LCV126.8 kW heating24 kW cooling7,234 kWh/yr | 1.5 | $2,315 | |
| Daikin RZYQ10TY1 / FDYQ250LCV126.8 kW heating24 kW cooling7,214 kWh/yr | 2 | $2,308 | |
| Toshiba RAV-GM2801AT8-A/RAV-RM2801DTP-E227 kW heating24 kW cooling7,059 kWh/yr | 1.5 | $2,259 | |
| Mitsubishi Heavy Industries FDCA250VSA-W/FDUA250VH28 kW heating23.5 kW cooling6,676 kWh/yr | 2 | $2,136 |
Other Actron Air models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Actron Air SCA260C/SCG260E25.3 kW heating24.7 kW cooling7,953 kWh/yr | 1.5 | $2,545 |
Compare CRV25BT / EVV25BS with another model
Actron Air CRV25BT specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 25.00 kW
- Cooling power input
- 7.27 kW
- Rated heating capacity (7 Β°C)
- 26.00 kW
- Heating power input
- 6.84 kW
- EER, full load (tested)
- 3.43
- COP, full load (tested)
- 3.78
- Rated AEER
- 3.42
- Rated ACOP
- 3.78
- Standby power (PIA)
- 14.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- Australia
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Actron Air CRV25BT zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 2,885 | 3,059 |
| Coldresidential | residential | 3.0 | 2.0 | 1,517 | 9,731 |
| Mixedcommercial | commercial | β | β | 3,878 | 1,568 |
| Mixedresidential | residential | 2.5 | 2.5 | 2,369 | 3,543 |
| Hotcommercial | commercial | β | β | 8,919 | 329 |
| Hotresidential | residential | 3.0 | 3.0 | 6,937 | 516 |
Part-load test points (18 values)
- h__h2_ext_cap_power_rated
- 6938 W
- c__t1_half_cap_power_rated
- 3054 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 2527 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 20850 W
- h__h1_half_cap_heat_cap_rated
- 12415 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_half_cap_power_rated
- 2377 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 12365 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_half_cap_cooling_cap_rated
- 12517 W
Other model numbers on registration AAC8793
Registered together and sharing the same test results. Usually variants of the same unit.
Australian GEMS registration details
- Registration number
- AAC8793
- GEMS registration id
- 167620
- Status
- approved, available (self-reported)
- Registration expires
- 15 April 2030
- Registered for sale in
- Australia, New Zealand
- Family
- CRV25BT / EVV25BS
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 11
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.