c/kWh
Energy rating (cooling)
3.5
Heating: 3
Annual electricity use
1,479 kWh
549 cooling + 930 heating
Estimated running cost
$473 / year
$39 / month Β· $4,733 over 10 years
Capacity
7.3 kW cooling
7.7 kW heating

15% less electricity than the median of 78 comparable 7 kW reverse cycle ducted split system registrations (1,746 kWh a year) in the mixed zone. Uses less than 85% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 64% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Actron Air LRC-071CS running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,793$894$8,938
Mixed zone 1,479$473$4,733
Hot zone 1,657$530$5,302

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners similar to the Actron Air LRC-071CS

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Midea UCMI70OB/DUCMI70IB7.4 kW heating7.3 kW cooling1,488 kWh/yr3.5$476
Aurora AU-BS24HR-2A-O / AU-LCF24-2A-I7.5 kW heating7.3 kW cooling1,463 kWh/yr3.5$468
Kaden KDI24 / KDI247.5 kW heating7.3 kW cooling1,479 kWh/yr4$473
Rinnai DONSR07B1LA/DINLR07B1A7.5 kW heating7.3 kW cooling1,464 kWh/yr4$468
Rinnai DONSR07B1/DINLR07B17.5 kW heating7.3 kW cooling1,463 kWh/yr3.5$468
Midea UCMI70OC/DUCMI70IC7.5 kW heating7.3 kW cooling1,464 kWh/yr4$468
Kaden KDI-7.07.5 kW heating7.3 kW cooling1,464 kWh/yr4$468
Carrier 38QSP070N8/42QSP070N87.5 kW heating7.3 kW cooling1,464 kWh/yr4$468

Compare LRC-071CS / LRE-071CS with another model

Actron Air LRC-071CS specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
7.30 kW
Cooling power input
2.06 kW
Rated heating capacity (7 Β°C)
7.70 kW
Heating power input
1.73 kW
EER, full load (tested)
3.49
COP, full load (tested)
4.40
Rated AEER
3.49
Rated ACOP
4.37
Standby power (PIA)
10.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Actron Air LRC-071CS zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––948789
Coldresidential3.52.53512,442
Mixedcommercial––2,396421
Mixedresidential3.53.0549930
Hotcommercial––1,648100
Hotresidential4.53.51,506151
Part-load test points (20 values)
c__t1_min_cap_power_rated
550 W
h__h1_min_cap_power_rated
366 W
h__h2_ext_cap_power_rated
2691 W
c__t1_half_cap_power_rated
1113 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
696 W
h__h1_have_min_cap_results
Yes
h__h1_min_cap_heat_cap_rated
1860 W
h__h2_ext_cap_heat_cap_rated
7875 W
h__h1_half_cap_heat_cap_rated
3710 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
275 W
c__t1_min_cap_cooling_cap_rated
2800 W
c__low_temp_full_cap_power_rated
1882.8400000000001 W
c__low_temp_half_cap_power_rated
598 W
c__t1_half_cap_cooling_cap_rated
3850 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2200 W
c__low_temp_full_cap_cooling_cap_rated
7862.099999999999 W
c__low_temp_half_cap_cooling_cap_rated
3650 W

Australian GEMS registration details

Registration number
AAC6915
GEMS registration id
146381
Status
approved, available (self-reported)
Registration expires
30 August 2027
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 10

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.