c/kWh
Energy rating (cooling)
2
Heating: 2.5
Annual electricity use
2,050 kWh
811 cooling + 1,239 heating
Estimated running cost
$656 / year
$55 / month Β· $6,560 over 10 years
Capacity
8 kW cooling
9 kW heating

12% more electricity than the median of 9 comparable 8 kW reverse cycle multi-split / vrf registrations (1,839 kWh a year) in the mixed zone. Uses less than 11% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 50% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Actron Air MMV-080CS running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,821$1,223$12,227
Mixed zone 2,050$656$6,560
Hot zone 2,497$799$7,990

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 8 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Mitsubishi Heavy Industries SCM71ZS-W8.6 kW heating7.1 kW cooling1,524 kWh/yr4$488
Kinghome KWHD(24)NK6PO8.3 kW heating7.3 kW cooling1,644 kWh/yr3$526
Mitsubishi Heavy Industries SCM80ZS-W9.3 kW heating8 kW cooling1,719 kWh/yr3.5$550
Kinghome KWHD(28)NK6PO8.8 kW heating8.2 kW cooling1,721 kWh/yr3.5$551
Midea MDV-V80WHN8(At)7.2 kW heating7.2 kW cooling1,733 kWh/yr2$555

Air conditioners similar to the Actron Air MMV-080CS

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Midea MV8M-80WV2N89 kW heating8 kW cooling2,050 kWh/yr2$656
Mitsubishi Heavy Industries SCM80ZS-W9.3 kW heating8 kW cooling1,719 kWh/yr3.5$550
Carrier 38VS00318SHCSS9 kW heating8 kW cooling1,787 kWh/yr3$572
Toshiba MCY-MHP0305HT9 kW heating8 kW cooling1,787 kWh/yr3$572
Mdv MV8M-80WV2N89 kW heating8 kW cooling2,050 kWh/yr2$656
Kinghome KWHD(28)NK6PO8.8 kW heating8.2 kW cooling1,721 kWh/yr3.5$551
LG 4MXM80MA09.2 kW heating8.2 kW cooling1,839 kWh/yr3$588
LG UHXM90MA110.1 kW heating8.8 kW cooling2,320 kWh/yr3$742

Compare MMV-080CS with another model

Actron Air MMV-080CS specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
8.00 kW
Cooling power input
2.24 kW
Rated heating capacity (7 Β°C)
9.00 kW
Heating power input
2.24 kW
EER, full load (tested)
3.65
COP, full load (tested)
4.06
Rated AEER
3.48
Rated ACOP
3.92
Standby power (PIA)
17.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
71 dB(A)
Demand response (AS/NZS 4755)
No
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Actron Air MMV-080CS zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,1241,063
Coldresidential2.02.05303,291
Mixedcommercial––1,402563
Mixedresidential2.02.58111,239
Hotcommercial––3,059139
Hotresidential2.53.02,288209
Part-load test points (18 values)
c__t1_half_cap_power_rated
880 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
910 W
h__h1_have_min_cap_results
No
h__h2_full_cap_power_rated
2400 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_half_cap_heat_cap_rated
4500 W
h__h2_full_cap_heat_cap_rated
7600 W
h__h2_is_capable_extended_load
No
c__low_temp_full_cap_power_rated
2047.3600000000001 W
c__low_temp_half_cap_power_rated
804.32 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
4000 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
8616 W
c__low_temp_half_cap_cooling_cap_rated
4308 W

Australian GEMS registration details

Registration number
AAC7937
GEMS registration id
156814
Status
approved, available (self-reported)
Registration expires
4 December 2028
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 19

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.