c/kWh
Energy rating (cooling)
2.5
Heating: 2.5
Annual electricity use
3,542 kWh
1,374 cooling + 2,168 heating
Estimated running cost
$1,133 / year
$94 / month Β· $11,334 over 10 years
Capacity
14 kW cooling
16 kW heating

About the same electricity as the median of 22 comparable 14 kW reverse cycle multi-split / vrf registrations (3,542 kWh a year) in the mixed zone. Uses less than 27% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 29% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Actron Air MMV-140CT running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 6,767$2,165$21,654
Mixed zone 3,542$1,133$11,334
Hot zone 4,307$1,378$13,782

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 14 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Samsung Electronics AJ125TXJ5KH/AJ025TNAPKH13.5 kW heating12.5 kW cooling2,930 kWh/yr2.5$938
Smart User SMV-V180W/N119 kW heating15.5 kW cooling3,113 kWh/yr3.5$996
Carrier 38VS005181HCSG16 kW heating14 kW cooling3,190 kWh/yr3$1,021
Toshiba MCY-MHP0504HS-A16 kW heating14 kW cooling3,190 kWh/yr3$1,021
Ers Tech ERS-AC24KWH19.5 kW heating15.5 kW cooling3,193 kWh/yr3.5$1,022

Air conditioners similar to the Actron Air MMV-140CT

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Fujitsu AJT045LCLCH14 kW heating14 kW cooling3,339 kWh/yr2.5$1,068
Hisense AVW-48HJFAH116 kW heating14 kW cooling3,214 kWh/yr3.5$1,028
Daikin RSUYQ5A2VMA16 kW heating14 kW cooling3,255 kWh/yr2.5$1,042
Daikin RSUYQ5AVMA16 kW heating14 kW cooling3,253 kWh/yr2.5$1,041
Toshiba MCY-MHP0504HS-A16 kW heating14 kW cooling3,190 kWh/yr3$1,021
Midea MDV-V140WHN8(At)14 kW heating14 kW cooling3,486 kWh/yr2$1,116
Hisense AVW-48HJFHH216 kW heating14 kW cooling3,365 kWh/yr3$1,077
Carrier 38VS005181HCSG16 kW heating14 kW cooling3,190 kWh/yr3$1,021

Compare MMV-140CT with another model

Actron Air MMV-140CT specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
14.00 kW
Cooling power input
4.12 kW
Rated heating capacity (7 Β°C)
16.00 kW
Heating power input
3.86 kW
EER, full load (tested)
3.40
COP, full load (tested)
4.16
Rated AEER
3.35
Rated ACOP
4.08
Standby power (PIA)
17.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
71 dB(A)
Demand response (AS/NZS 4755)
No
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Actron Air MMV-140CT zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,9021,868
Coldresidential2.52.08815,886
Mixedcommercial––2,393969
Mixedresidential2.52.51,3742,168
Hotcommercial––5,311217
Hotresidential3.03.03,972335
Part-load test points (18 values)
c__t1_half_cap_power_rated
1500 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1600 W
h__h1_have_min_cap_results
No
h__h2_full_cap_power_rated
3650 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_half_cap_heat_cap_rated
8000 W
h__h2_full_cap_heat_cap_rated
12300 W
h__h2_is_capable_extended_load
No
c__low_temp_full_cap_power_rated
3765.6800000000003 W
c__low_temp_half_cap_power_rated
1371 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
7000 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
15078 W
c__low_temp_half_cap_cooling_cap_rated
7539 W

Australian GEMS registration details

Registration number
AAC7916
GEMS registration id
156859
Status
approved, available (self-reported)
Registration expires
28 November 2028
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 20

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.