c/kWh
Energy rating (cooling)
3.5
Heating: 2.5
Annual electricity use
2,885 kWh
1,073 cooling + 1,812 heating
Estimated running cost
$923 / year
$77 / month Β· $9,232 over 10 years
Capacity
14 kW cooling
14.3 kW heating

19% less electricity than the median of 117 comparable 14 kW reverse cycle ducted split system registrations (3,549 kWh a year) in the mixed zone. Uses less than 97% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 38% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Actron Air URC-140CS running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,513$1,764$17,642
Mixed zone 2,885$923$9,232
Hot zone 3,339$1,068$10,685

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 14 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Brivis AONSR15B1/AINHU15B115.7 kW heating13.6 kW cooling2,497 kWh/yr5$799
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling2,556 kWh/yr3.5$818
Rinnai DONSR13B1/DINLR13B113 kW heating12.5 kW cooling2,559 kWh/yr3.5$819
Carrier 38QSH125D8S-1/42QSH125D8S-112.8 kW heating12.4 kW cooling2,581 kWh/yr3.5$826
Kaden KDI42 / KDI4213 kW heating12.5 kW cooling2,587 kWh/yr3.5$828

Air conditioners similar to the Actron Air URC-140CS

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Kaden KDI48 / KDI4814 kW heating14 kW cooling2,861 kWh/yr3.5$916
Pioneer International VPC-48A114 kW heating14 kW cooling2,988 kWh/yr3.5$956
Mdv C-UV-140N8-QC3W / CDV-140HFN8-QC3W14.5 kW heating14 kW cooling2,951 kWh/yr3.5$944
Carrier 38QSV140N8E/42QSV140N8H15.5 kW heating14 kW cooling2,996 kWh/yr3.5$959
Pioneer International VPC-48A1/VPE-48A114 kW heating14 kW cooling2,988 kWh/yr3.5$956
Rinnai DONSR15B1/DINLR15B114.5 kW heating14 kW cooling2,930 kWh/yr3.5$938
Midea UCMI140OB/DUCMI140IHB14.5 kW heating14 kW cooling2,943 kWh/yr3.5$942
Kaden KDI-14.015.5 kW heating14 kW cooling2,996 kWh/yr3.5$959

Compare URC-140CS / LRE-140CS with another model

Actron Air URC-140CS specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
14.00 kW
Cooling power input
4.11 kW
Rated heating capacity (7 Β°C)
14.35 kW
Heating power input
3.46 kW
EER, full load (tested)
3.32
COP, full load (tested)
4.04
Rated AEER
3.38
Rated ACOP
4.11
Standby power (PIA)
10.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Actron Air URC-140CS zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––6411,521
Coldresidential4.02.06724,841
Mixedcommercial––1,232791
Mixedresidential3.52.51,0731,812
Hotcommercial––3,332171
Hotresidential4.03.03,070269
Part-load test points (20 values)
c__t1_min_cap_power_rated
893 W
h__h1_min_cap_power_rated
562 W
h__h2_ext_cap_power_rated
5061 W
c__t1_half_cap_power_rated
1733 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1299 W
h__h1_have_min_cap_results
Yes
h__h1_min_cap_heat_cap_rated
2800 W
h__h2_ext_cap_heat_cap_rated
14140 W
h__h1_half_cap_heat_cap_rated
6490 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
531 W
c__t1_min_cap_cooling_cap_rated
3215 W
c__low_temp_full_cap_power_rated
3756.54 W
c__low_temp_half_cap_power_rated
1094 W
c__t1_half_cap_cooling_cap_rated
6560 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3770 W
c__low_temp_full_cap_cooling_cap_rated
15078 W
c__low_temp_half_cap_cooling_cap_rated
7100 W

Australian GEMS registration details

Registration number
AAC6917
GEMS registration id
146395
Status
approved, available (self-reported)
Registration expires
30 August 2027
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.