Actron Air URC-140CS / LRE-140CS is a 14 kW reverse cycle ducted split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC6917).
- Energy rating (cooling)
- 3.5
- Heating: 2.5
- Annual electricity use
- 2,885 kWh
- 1,073 cooling + 1,812 heating
- Estimated running cost
- $923 / year
- $77 / month Β· $9,232 over 10 years
- Capacity
- 14 kW cooling
- 14.3 kW heating
19% less electricity than the median of 117 comparable 14 kW reverse cycle ducted split system registrations (3,549 kWh a year) in the mixed zone. Uses less than 97% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 38% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Actron Air URC-140CS running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 5,513 | $1,764 | $17,642 |
| Mixed zone | 2,885 | $923 | $9,232 |
| Hot zone | 3,339 | $1,068 | $10,685 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 14 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Brivis AONSR15B1/AINHU15B115.7 kW heating13.6 kW cooling2,497 kWh/yr | 5 | $799 | |
| Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling2,556 kWh/yr | 3.5 | $818 | |
| Rinnai DONSR13B1/DINLR13B113 kW heating12.5 kW cooling2,559 kWh/yr | 3.5 | $819 | |
| Carrier 38QSH125D8S-1/42QSH125D8S-112.8 kW heating12.4 kW cooling2,581 kWh/yr | 3.5 | $826 | |
| Kaden KDI42 / KDI4213 kW heating12.5 kW cooling2,587 kWh/yr | 3.5 | $828 |
Air conditioners similar to the Actron Air URC-140CS
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Kaden KDI48 / KDI4814 kW heating14 kW cooling2,861 kWh/yr | 3.5 | $916 | |
| Pioneer International VPC-48A114 kW heating14 kW cooling2,988 kWh/yr | 3.5 | $956 | |
| Mdv C-UV-140N8-QC3W / CDV-140HFN8-QC3W14.5 kW heating14 kW cooling2,951 kWh/yr | 3.5 | $944 | |
| Carrier 38QSV140N8E/42QSV140N8H15.5 kW heating14 kW cooling2,996 kWh/yr | 3.5 | $959 | |
| Pioneer International VPC-48A1/VPE-48A114 kW heating14 kW cooling2,988 kWh/yr | 3.5 | $956 | |
| Rinnai DONSR15B1/DINLR15B114.5 kW heating14 kW cooling2,930 kWh/yr | 3.5 | $938 | |
| Midea UCMI140OB/DUCMI140IHB14.5 kW heating14 kW cooling2,943 kWh/yr | 3.5 | $942 | |
| Kaden KDI-14.015.5 kW heating14 kW cooling2,996 kWh/yr | 3.5 | $959 |
Compare URC-140CS / LRE-140CS with another model
Actron Air URC-140CS specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 14.00 kW
- Cooling power input
- 4.11 kW
- Rated heating capacity (7 Β°C)
- 14.35 kW
- Heating power input
- 3.46 kW
- EER, full load (tested)
- 3.32
- COP, full load (tested)
- 4.04
- Rated AEER
- 3.38
- Rated ACOP
- 4.11
- Standby power (PIA)
- 10.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Actron Air URC-140CS zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 641 | 1,521 |
| Coldresidential | residential | 4.0 | 2.0 | 672 | 4,841 |
| Mixedcommercial | commercial | β | β | 1,232 | 791 |
| Mixedresidential | residential | 3.5 | 2.5 | 1,073 | 1,812 |
| Hotcommercial | commercial | β | β | 3,332 | 171 |
| Hotresidential | residential | 4.0 | 3.0 | 3,070 | 269 |
Part-load test points (20 values)
- c__t1_min_cap_power_rated
- 893 W
- h__h1_min_cap_power_rated
- 562 W
- h__h2_ext_cap_power_rated
- 5061 W
- c__t1_half_cap_power_rated
- 1733 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 1299 W
- h__h1_have_min_cap_results
- Yes
- h__h1_min_cap_heat_cap_rated
- 2800 W
- h__h2_ext_cap_heat_cap_rated
- 14140 W
- h__h1_half_cap_heat_cap_rated
- 6490 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 531 W
- c__t1_min_cap_cooling_cap_rated
- 3215 W
- c__low_temp_full_cap_power_rated
- 3756.54 W
- c__low_temp_half_cap_power_rated
- 1094 W
- c__t1_half_cap_cooling_cap_rated
- 6560 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 3770 W
- c__low_temp_full_cap_cooling_cap_rated
- 15078 W
- c__low_temp_half_cap_cooling_cap_rated
- 7100 W
Australian GEMS registration details
- Registration number
- AAC6917
- GEMS registration id
- 146395
- Status
- approved, available (self-reported)
- Registration expires
- 30 August 2027
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 11
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.