c/kWh
Energy rating (cooling)
6.5
Heating: 3.5
Annual electricity use
404 kWh
133 cooling + 271 heating
Estimated running cost
$129 / year
$11 / month Β· $1,293 over 10 years
Capacity
2.6 kW cooling
2.7 kW heating

26% less electricity than the median of 192 comparable 2.5 kW reverse cycle split system registrations (544 kWh a year) in the mixed zone. Uses less than 99% of them.

Across all 3,681 air conditioner registrations sold in Australia, it uses less than 96% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Actron Air WRC-026DS running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 790$253$2,528
Mixed zone 404$129$1,293
Hot zone 423$135$1,354

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners similar to the Actron Air WRC-026DS

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Midea MFEP26VB-W/MFEP26VB-N2.7 kW heating2.6 kW cooling404 kWh/yr6.5$129
Kogan KASHSAC26UA2.9 kW heating2.6 kW cooling497 kWh/yr5$159
Aux ASW-H27A4/FAR3DI2.9 kW heating2.6 kW cooling497 kWh/yr5$159
Kogan KASHSAC26UC2.9 kW heating2.6 kW cooling497 kWh/yr5$159
Akai AK-TP26M2.9 kW heating2.6 kW cooling497 kWh/yr5$159
Rinnai HONRT25B / HINRT25B2.9 kW heating2.6 kW cooling465 kWh/yr7$149
TECO TWS-TSO26H3DVHA2.9 kW heating2.6 kW cooling497 kWh/yr5$159
Rinnai HONRJ25B / HINRJ25B2.9 kW heating2.6 kW cooling465 kWh/yr7$149

Compare WRC-026DS / WRE-026DS with another model

Actron Air WRC-026DS specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
2.63 kW
Cooling power input
0.49 kW
Rated heating capacity (7 Β°C)
2.70 kW
Heating power input
0.50 kW
EER, full load (tested)
5.31
COP, full load (tested)
5.44
Rated AEER
5.38
Rated ACOP
5.39
Standby power (PIA)
0.4 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
56.6 dB(A)
Outdoor sound power
63.7 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Actron Air WRC-026DS zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––74230
Coldresidential7.03.584706
Mixedcommercial––155123
Mixedresidential6.53.5133271
Hotcommercial––39925
Hotresidential7.04.038340
Part-load test points (23 values)
c__t1_min_cap_power_rated
183 W
h__h1_min_cap_power_rated
185 W
h__h2_ext_cap_power_rated
1037 W
c__t1_half_cap_power_rated
245 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
225 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1140 W
h__h2_ext_cap_heat_cap_rated
3230 W
h__h1_half_cap_heat_cap_rated
1400 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
108 W
c__t1_min_cap_cooling_cap_rated
1000 W
c__low_temp_half_cap_power_rated
143 W
c__t1_half_cap_cooling_cap_rated
1290 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
1050 W
c__low_temp_half_cap_cooling_cap_rated
1300 W

Australian GEMS registration details

Registration number
AAC9008
GEMS registration id
170171
Status
approved, available (self-reported)
Registration expires
17 June 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.