c/kWh
Energy rating (cooling)
0
Heating: 0
Annual electricity use
2,576 kWh
1,117 cooling + 1,459 heating
Estimated running cost
$824 / year
$69 / month Β· $8,243 over 10 years
Capacity
3.5 kW cooling
2.8 kW heating

2% more electricity than the median of 22 comparable 3.5 kW reverse cycle portable registrations (2,538 kWh a year) in the mixed zone. Uses less than 41% of them.

Across all 3,681 air conditioner registrations sold in Australia, it uses less than 42% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Alfordson PAC-12-H running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,731$1,194$11,939
Mixed zone 2,576$824$8,243
Hot zone 3,302$1,057$10,566

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 3.5 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
TCL TAC-12CHPB/NXBp2.9 kW heating3.5 kW cooling1,865 kWh/yr0$597
TCL TAC-12CHPB/NWBp2.9 kW heating3.5 kW cooling1,865 kWh/yr0$597
Arlec PA1123BKHA2.6 kW heating3.3 kW cooling2,324 kWh/yr0$744
Carrier 51QPD12N7S-12.9 kW heating3.3 kW cooling2,353 kWh/yr0$753
Midea MPPD33H2.8 kW heating3.4 kW cooling2,353 kWh/yr0$753

Air conditioners similar to the Alfordson PAC-12-H

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
TCL TAC-12CHPB/NYBp2.9 kW heating3.5 kW cooling1,865 kWh/yr0$597
Goldair 3.5kW H & C PAC2.8 kW heating3.5 kW cooling2,538 kWh/yr0$812
Polo PC35RWF3 kW heating3.5 kW cooling2,483 kWh/yr0$795
Olimpia Splendid 024042.9 kW heating3.5 kW cooling2,401 kWh/yr0$768
Bonaire PRC60001352.8 kW heating3.5 kW cooling2,538 kWh/yr0$812
Goldair GPPAC3002.8 kW heating3.5 kW cooling2,538 kWh/yr0$812
Rinnai RPC35PDRWF3 kW heating3.5 kW cooling2,458 kWh/yr0$787
TCL TAC-12CHPB/NUBp2.9 kW heating3.5 kW cooling1,865 kWh/yr0$597

Compare PAC-12-H with another model

Alfordson PAC-12-H specifications

Type
Reverse cycle
Configuration
Portable
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
3.50 kW
Cooling power input
1.33 kW
Rated heating capacity (7 Β°C)
2.83 kW
Heating power input
1.13 kW
EER, full load (tested)
2.63
COP, full load (tested)
2.51
Rated AEER
2.63
Rated ACOP
2.50
Standby power (PIA)
–
Compressor
Fixed speed
Refrigerant
R290
Power supply
Single phase
Indoor sound power
64.8 dB(A)
Outdoor sound power
–
Demand response (AS/NZS 4755)
–
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Alfordson PAC-12-H zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldresidential0.00.07253,006
Mixedresidential0.00.01,1171,459
Hotresidential0.00.02,989313

Other model numbers on registration AAC9244

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC9244
GEMS registration id
172079
Status
approved, available (self-reported)
Registration expires
19 August 2030
Registered for sale in
Australia
Family
PAC-12-H
Regulatory standard
[Unitary Single-Duct] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.5:2015
MEPS
2019
Product class
Class 4

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.