c/kWh
Energy rating (cooling)
2
Heating: 1.5
Annual electricity use
4,897 kWh
1,981 cooling + 2,916 heating
Estimated running cost
$1,567 / year
$131 / month Β· $15,670 over 10 years
Capacity
17.8 kW cooling
17.8 kW heating

12% less electricity than the median of 10 comparable 18 kW reverse cycle ducted packaged registrations (5,554 kWh a year) in the mixed zone. Uses less than 90% of them.

Across all 3,638 air conditioner registrations sold in Australia, it uses less than 17% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

APAC P018AHR3TA-LI2061A running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 8,965$2,869$28,688
Mixed zone 4,897$1,567$15,670
Hot zone 6,170$1,974$19,744

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 17.8 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Temperzone OPA 171RLTFY17.3 kW heating16.4 kW cooling4,276 kWh/yr2.5$1,368
Temperzone OPA 171RLTFY17.3 kW heating16.4 kW cooling4,414 kWh/yr2.5$1,412
Actron Air PRV19BT-T19 kW heating19 kW cooling4,505 kWh/yr2.5$1,442
APAC P015AHR3SA-LTT14.2 kW heating16 kW cooling4,561 kWh/yr1.5$1,460
APAC P015AVR3SA-LTR14.2 kW heating16 kW cooling4,561 kWh/yr1.5$1,460

Air conditioners similar to the APAC P018AHR3TA-LI2061A

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Temperzone OPA 186RKTYG17.5 kW heating17.8 kW cooling5,611 kWh/yr1.5$1,796
AIRSTAGE RAQ/K/WP/1718.5 kW heating17.9 kW cooling5,919 kWh/yr1.5$1,894
AIRSTAGE RAQ/K/WP/ECO/1718.5 kW heating17.9 kW cooling5,919 kWh/yr1.5$1,894
Daikin UAYN180AFY1A17.2 kW heating17.4 kW cooling5,998 kWh/yr1.5$1,919
Temperzone OPA186RKTY16.7 kW heating18.2 kW cooling5,378 kWh/yr1.5$1,721
Actron Air PRV17AT-T18.4 kW heating17 kW cooling5,833 kWh/yr2$1,867
Actron Air PRV19BT-T19 kW heating19 kW cooling4,505 kWh/yr2.5$1,442

Other APAC models of similar capacity

ModelStarsEst. cost / yrCompare
APAC P018AVR3SA-LTT16.1 kW heating18.7 kW cooling5,406 kWh/yr1.5$1,730

Compare P018AHR3TA-LI2061A with another model

APAC P018AHR3TA-LI2061A specifications

Type
Reverse cycle
Configuration
Packaged
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
17.78 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
17.78 kW
Heating power input
–
EER, full load (tested)
3.25
COP, full load (tested)
3.83
Rated AEER
3.31
Rated ACOP
3.91
Standby power (PIA)
29.8 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Australia, Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

APAC P018AHR3TA-LI2061A zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––2,7642,622
Coldresidential2.01.51,2977,668
Mixedcommercial––3,4741,374
Mixedresidential2.01.51,9812,916
Hotcommercial––7,592328
Hotresidential2.52.05,674496
Part-load test points (23 values)
c__t1_min_cap_power_rated
2350 W
h__h1_min_cap_power_rated
2020 W
h__h2_ext_cap_power_rated
4470 W
c__t1_half_cap_power_rated
2350 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
2210 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
7400 W
h__h2_ext_cap_heat_cap_rated
13470 W
h__h1_half_cap_heat_cap_rated
8580 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
2070 W
c__t1_min_cap_cooling_cap_rated
8770 W
c__low_temp_half_cap_power_rated
2070 W
c__t1_half_cap_cooling_cap_rated
8770 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
9340 W
c__low_temp_half_cap_cooling_cap_rated
9340 W

Other model numbers on registration AAC10268

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC10268
GEMS registration id
–
Status
approved
Registration expires
29 June 2031
Registered for sale in
Australia, New Zealand
Family
P018AHR3TA-
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
6