c/kWh
Energy rating (cooling)
1.5
Heating: 1.5
Annual electricity use
6,827 kWh
2,867 cooling + 3,960 heating
Estimated running cost
$2,185 / year
$182 / month Β· $21,846 over 10 years
Capacity
22.4 kW cooling
22.7 kW heating

14% more electricity than the median of 15 comparable 20 kW reverse cycle ducted packaged registrations (5,980 kWh a year) in the mixed zone. Uses less than 20% of them.

Across all 3,638 air conditioner registrations sold in Australia, it uses less than 12% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

APAC P023AVR3SA-LTT running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 11,916$3,813$38,131
Mixed zone 6,827$2,185$21,846
Hot zone 8,990$2,877$28,768

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 22.4 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Temperzone OPA 211RLTFY19.7 kW heating19.9 kW cooling4,766 kWh/yr2.5$1,525
Temperzone OPA 211RLTFY19.7 kW heating19.9 kW cooling4,846 kWh/yr2.5$1,551
Actron Air PRV22AT23 kW heating22 kW cooling5,387 kWh/yr2.5$1,724
Actron Air PKV240T-T23.4 kW heating20.8 kW cooling5,980 kWh/yr2$1,914
APAC P020AHR3SA-RBB18.9 kW heating22.4 kW cooling6,372 kWh/yr1.5$2,039

Air conditioners similar to the APAC P023AVR3SA-LTT

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Temperzone OPA242RKTB22 kW heating22.4 kW cooling7,114 kWh/yr1.5$2,276
Actron Air PRV22AT23 kW heating22 kW cooling5,387 kWh/yr2.5$1,724
Actron Air PCG233U23.6 kW heating22.9 kW cooling6,986 kWh/yr1.5$2,236
AIRSTAGE RAQ/IL/EC/WP/11024.3 kW heating23.8 kW cooling7,081 kWh/yr2$2,266
Aggreko RPA-020S-R410A23.4 kW heating21 kW cooling7,509 kWh/yr1.5$2,403
Coates RPA-C02023.4 kW heating21 kW cooling7,509 kWh/yr1.5$2,403

Other APAC models of similar capacity

ModelStarsEst. cost / yrCompare
APAC P023AHR3SA-LRR22.7 kW heating22.4 kW cooling6,827 kWh/yr1.5$2,185
APAC P023AHR3SA-RTT22.7 kW heating22.4 kW cooling6,827 kWh/yr1.5$2,185

Compare P023AVR3SA-LTT with another model

APAC P023AVR3SA-LTT specifications

Type
Reverse cycle
Configuration
Packaged
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
22.40 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
22.73 kW
Heating power input
–
EER, full load (tested)
3.17
COP, full load (tested)
3.61
Rated AEER
3.28
Rated ACOP
3.73
Standby power (PIA)
28.5 W
Compressor
Fixed speed
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
No
Country of manufacture
Australia, Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

APAC P023AVR3SA-LTT zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––4,2613,375
Coldresidential1.51.01,90410,012
Mixedcommercial––5,2741,832
Mixedresidential1.51.52,8673,960
Hotcommercial––11,375426
Hotresidential1.51.58,325665
Part-load test points (6 values)
h__h2_full_cap_power_rated
5560 W
h__h3_have_full_cap_results
No
h__h2_full_cap_heat_cap_rated
18700 W
c__low_temp_full_cap_power_rated
6040 W
c__low_temp_have_full_cap_results
Yes
c__low_temp_full_cap_cooling_cap_rated
23960 W

Other model numbers on registration AAC7381

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC7381
GEMS registration id
–
Status
approved
Registration expires
27 March 2028
Registered for sale in
Australia, New Zealand
Family
P023AVR3SA-
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
6

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.