c/kWh
Energy rating (cooling)
1.5
Heating: 1
Annual electricity use
5,406 kWh
2,268 cooling + 3,138 heating
Estimated running cost
$1,730 / year
$144 / month Β· $17,299 over 10 years
Capacity
18.7 kW cooling
16.1 kW heating

24% more electricity than the median of 53 comparable 18 kW reverse cycle ducted split system registrations (4,376 kWh a year) in the mixed zone. Uses less than 15% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 16% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

APAC S018OVR3SA running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 9,284$2,971$29,709
Mixed zone 5,406$1,730$17,299
Hot zone 6,990$2,237$22,368

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 18.7 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Mitsubishi Heavy Industries FDCA200VSA-W/FDUA200VH22.4 kW heating20 kW cooling1,784 kWh/yr2$571
AirSmart IES-70015.8 kW heating17 kW cooling3,358 kWh/yr3.5$1,075
AirSmart IES-***15.8 kW heating17 kW cooling3,358 kWh/yr3.5$1,075
Actron Air LRC-170CS / LRE-170CS17.6 kW heating16.6 kW cooling3,556 kWh/yr3.5$1,138
Midea DUCMI170IHB/UCMI170OB17.5 kW heating17 kW cooling3,585 kWh/yr3.5$1,147

Air conditioners similar to the APAC S018OVR3SA

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Actron Air CRV19BT / EVV19BS19 kW heating19 kW cooling4,418 kWh/yr2.5$1,414
Actron Air CRV19BT / EAA19BS & EFV19BS19 kW heating19 kW cooling4,418 kWh/yr2.5$1,414
Temperzone OSA 211RLTFH / ISD 211LYX20.8 kW heating19 kW cooling6,228 kWh/yr1.5$1,993
Gree GFH65DEXL-S6DND7D/O / GFH65DEXL-S6DND7D/I19.5 kW heating18 kW cooling4,234 kWh/yr3$1,355
Daikin RZAS180DY1 / FDYA180AV120 kW heating18 kW cooling4,153 kWh/yr2.5$1,329
Braemar KCHB180D1B/KDHB180D1S19.5 kW heating18 kW cooling4,234 kWh/yr3$1,355
Daikin RZAS180DV1 / FDYA180AV120 kW heating18 kW cooling4,128 kWh/yr2.5$1,321
Tosot TFH65DEXL-S6DND7D/O / TFH65DEXL-S6DND7D/I19.5 kW heating18 kW cooling4,234 kWh/yr3$1,355

Compare S018OVR3SA / S018IVR3SA-TR with another model

APAC S018OVR3SA specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
18.74 kW
Cooling power input
4.95 kW
Rated heating capacity (7 Β°C)
16.06 kW
Heating power input
4.68 kW
EER, full load (tested)
3.58
COP, full load (tested)
3.28
Rated AEER
3.67
Rated ACOP
3.32
Standby power (PIA)
46.8 W
Compressor
Fixed speed
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
No
Country of manufacture
Australia, Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

APAC S018OVR3SA zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––3,4032,659
Coldresidential1.51.01,5277,757
Mixedcommercial––4,1521,476
Mixedresidential1.51.02,2683,138
Hotcommercial––8,789382
Hotresidential2.01.06,411579
Part-load test points (6 values)
h__h2_full_cap_power_rated
4310 W
h__h3_have_full_cap_results
No
h__h2_full_cap_heat_cap_rated
13230 W
c__low_temp_full_cap_power_rated
4480 W
c__low_temp_have_full_cap_results
Yes
c__low_temp_full_cap_cooling_cap_rated
19450 W

Other model numbers on registration AAC7458

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC7458
GEMS registration id
153266
Status
approved, available (self-reported)
Registration expires
1 May 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
S018OVR3SA / S018ILR1SA-
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: rinnai.com.au. How the derived figures are calculated.