c/kWh
Energy rating (cooling)
1.5
Heating: 1
Annual electricity use
6,987 kWh
3,168 cooling + 3,819 heating
Estimated running cost
$2,236 / year
$186 / month Β· $22,358 over 10 years
Capacity
23.4 kW cooling
20.4 kW heating

3% less electricity than the median of 17 comparable 25 kW reverse cycle ducted split system registrations (7,214 kWh a year) in the mixed zone. Uses less than 65% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 11% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

APAC S024OVR3SA running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 11,785$3,771$37,712
Mixed zone 6,987$2,236$22,358
Hot zone 9,715$3,109$31,088

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 23.4 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Actron Air CRV22BT / EVV22BS23 kW heating22 kW cooling5,232 kWh/yr2.5$1,674
Actron Air CRV22BT / EAA22BS & EFV22BS23 kW heating22 kW cooling5,232 kWh/yr2.5$1,674
Panasonic U-224PZH3R8 / S-224PE4R25 kW heating22.4 kW cooling5,726 kWh/yr2.5$1,832
Haier 1U250S5SA2FB / AD250S5SH2FA25 kW heating22 kW cooling5,790 kWh/yr2.5$1,853
Fujitsu AOTH90KRTA/ARTH90KHTA25 kW heating22.4 kW cooling6,242 kWh/yr2$1,997

Air conditioners similar to the APAC S024OVR3SA

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Mitsubishi Heavy Industries FDCA250VSA-W/FDUA250VH28 kW heating23.5 kW cooling6,676 kWh/yr2$2,136
Daikin RZQ250LY1 / FDYQN250LBV126.8 kW heating23.5 kW cooling7,644 kWh/yr1.5$2,446
Daikin RZYQ10TY1 / FDYQ250LCV126.8 kW heating24 kW cooling7,214 kWh/yr2$2,308
Braemar SCHV24D3S/SDHV24D1S26 kW heating24 kW cooling7,557 kWh/yr1.5$2,418
Toshiba RAV-GM2801AT8-A/RAV-RM2801DTP-E227 kW heating24 kW cooling7,059 kWh/yr1.5$2,259
Actron Air CRA230T / EAA230S & EFA230S23.5 kW heating22.6 kW cooling6,918 kWh/yr1.5$2,214
Actron Air CRA230T / EVA230S23.5 kW heating22.6 kW cooling6,918 kWh/yr1.5$2,214
Temperzone ISD 251LYX / OSA 251RLTFH23.3 kW heating22.5 kW cooling7,493 kWh/yr1.5$2,398

Compare S024OVR3SA / S024ILR3SA-TR with another model

APAC S024OVR3SA specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
23.36 kW
Cooling power input
6.93 kW
Rated heating capacity (7 Β°C)
20.36 kW
Heating power input
6.08 kW
EER, full load (tested)
3.19
COP, full load (tested)
3.20
Rated AEER
3.30
Rated ACOP
3.27
Standby power (PIA)
43.7 W
Compressor
Variable speed
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
No
Country of manufacture
Australia, Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

APAC S024OVR3SA zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––5,1103,239
Coldresidential1.01.02,1089,677
Mixedcommercial––6,1711,764
Mixedresidential1.51.03,1683,819
Hotcommercial––12,619429
Hotresidential1.51.59,061654
Part-load test points (16 values)
c__t1_min_cap_power_rated
3830 W
h__h1_min_cap_power_rated
3090 W
h__h2_min_cap_power_rated
3100 W
c__t1_have_min_cap_results
Yes
h__h2_full_cap_power_rated
5600 W
h__h2_have_min_cap_results
Yes
h__h3_have_full_cap_results
No
h__h1_min_cap_heat_cap_rated
10600 W
h__h2_min_cap_heat_cap_rated
8480 W
h__h2_full_cap_heat_cap_rated
16170 W
c__low_temp_min_cap_power_rated
3550 W
c__t1_min_cap_cooling_cap_rated
11520 W
c__low_temp_full_cap_power_rated
6380 W
c__low_temp_have_full_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
11800 W
c__low_temp_full_cap_cooling_cap_rated
25040 W

Other model numbers on registration AAC7461

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC7461
GEMS registration id
153286
Status
approved, available (self-reported)
Registration expires
2 May 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
S024OVR3SA / S024IHR3SA-
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: rinnai.com.au. How the derived figures are calculated.