c/kWh
Energy rating (cooling)
2.5
Heating: 2
Annual electricity use
3,628 kWh
1,258 cooling + 2,370 heating
Estimated running cost
$1,161 / year
$97 / month Β· $11,610 over 10 years
Capacity
13.2 kW cooling
17 kW heating

14% more electricity than the median of 140 comparable 12.5 kW reverse cycle ducted split system registrations (3,178 kWh a year) in the mixed zone. Uses less than 11% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 27% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Braemar KCHV160D1B running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 7,336$2,348$23,475
Mixed zone 3,628$1,161$11,610
Hot zone 4,078$1,305$13,050

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 13.2 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Panasonic U-125PZ3R8 / S-1014PF3E12.1 kW heating12.1 kW cooling1,681 kWh/yr1.5$538
Brivis AONSR13B1/AINHU13B113.8 kW heating12 kW cooling2,209 kWh/yr4$707
Brivis AONSR15B1/AINHU15B115.7 kW heating13.6 kW cooling2,497 kWh/yr5$799
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling2,556 kWh/yr3.5$818
Rinnai DONSR13B1/DINLR13B113 kW heating12.5 kW cooling2,559 kWh/yr3.5$819

Air conditioners similar to the Braemar KCHV160D1B

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Actron Air CRV13AS / EAA13AS & EFV13AS13.4 kW heating13.2 kW cooling4,893 kWh/yr2.5$1,566
Actron Air CRV13AS / EVV13AS13.4 kW heating13.2 kW cooling4,893 kWh/yr2.5$1,566
Hisense AUW-125U4RH1/AUD-125UX4RSH115.5 kW heating13 kW cooling3,223 kWh/yr3$1,031
Temperzone OSAT 130RLSFH / ISDT 130LY15.5 kW heating13 kW cooling3,354 kWh/yr2.5$1,073
Rinnai DONSR12Z72/DINLR12Z7215 kW heating13 kW cooling3,036 kWh/yr3$972
Panasonic U-140PZ4R8 / S-1014PF3E13.4 kW heating13.4 kW cooling3,008 kWh/yr2.5$963
Panasonic U-140PZ4R5 / S-1014PF3E13.4 kW heating13.4 kW cooling3,008 kWh/yr2.5$963
Fujitsu AOTH54KBTA/ARTH54KMTAP15 kW heating13 kW cooling3,527 kWh/yr2.5$1,129

Compare KCHV160D1B/KGHV200A1T with another model

Braemar KCHV160D1B specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
13.20 kW
Cooling power input
3.90 kW
Rated heating capacity (7 Β°C)
17.00 kW
Heating power input
4.86 kW
EER, full load (tested)
3.40
COP, full load (tested)
3.46
Rated AEER
3.37
Rated ACOP
3.49
Standby power (PIA)
5.1 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China, Australia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Braemar KCHV160D1B zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,6051,982
Coldresidential3.01.58056,531
Mixedcommercial––2,105999
Mixedresidential2.52.01,2582,370
Hotcommercial––4,977200
Hotresidential3.03.03,757321
Part-load test points (23 values)
c__t1_min_cap_power_rated
780 W
h__h1_min_cap_power_rated
820 W
c__t1_half_cap_power_rated
1450 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1670 W
h__h1_have_min_cap_results
Yes
h__h2_full_cap_power_rated
4170 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
4000 W
h__h1_half_cap_heat_cap_rated
7660 W
h__h2_full_cap_heat_cap_rated
13200 W
h__h2_is_capable_extended_load
No
c__low_temp_min_cap_power_rated
620 W
c__t1_min_cap_cooling_cap_rated
2900 W
c__low_temp_full_cap_power_rated
3564.6 W
c__low_temp_half_cap_power_rated
1325.3 W
c__t1_half_cap_cooling_cap_rated
6400 W
c__low_temp_have_half_cap_results
No
c__low_temp_min_cap_cooling_cap_rated
3000 W
c__low_temp_full_cap_cooling_cap_rated
14216.4 W
c__low_temp_half_cap_cooling_cap_rated
6892.799999999999 W

Australian GEMS registration details

Registration number
AAC8526
GEMS registration id
165491
Status
approved, available (self-reported)
Registration expires
17 November 2029
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: gree.com. How the derived figures are calculated.