Australia Β· costs in AUD

Reverse cycle fixed air conditioner
Braemar NCHV10D14B Air Conditioner
Braemar NCHV10D14B is a 10.6 kW reverse cycle fixed air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC7927).
- Energy rating (cooling)
- 3.5
- Heating: 3
- Annual electricity use
- 2,217 kWh
- 827 cooling + 1,390 heating
- Estimated running cost
- $709 / year
- $59 / month Β· $7,094 over 10 years
- Capacity
- 10.6 kW cooling
- 11.4 kW heating
About the same electricity as the median of 9 comparable 10 kW reverse cycle fixed registrations (2,217 kWh a year) in the mixed zone. Uses less than 44% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 47% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Braemar NCHV10D14B running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 4,364 | $1,396 | $13,965 |
| Mixed zone | 2,217 | $709 | $7,094 |
| Hot zone | 2,596 | $831 | $8,307 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 10.6 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Haier 5U100S2PS1FA10 kW heating10 kW cooling2,140 kWh/yr | 3.5 | $685 |
Air conditioners similar to the Braemar NCHV10D14B
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Haier 5U100S2PS1FA10 kW heating10 kW cooling2,515 kWh/yr | 2.5 | $805 | |
| Hitachi RAM-G110N5HCE12 kW heating10 kW cooling2,226 kWh/yr | 3.5 | $712 | |
| Haier 5U100S2PS1FA10 kW heating10 kW cooling2,140 kWh/yr | 3.5 | $685 | |
| Daikin 5MXM100R2VMA11 kW heating10 kW cooling2,172 kWh/yr | 3 | $695 | |
| Rinnai MON5H11B12.3 kW heating11.5 kW cooling2,492 kWh/yr | 3.5 | $797 | |
| Rinnai MON5H11B12.3 kW heating11.5 kW cooling2,492 kWh/yr | 3.5 | $797 |
Other Braemar models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Braemar NCHV10D1410.8 kW heating10.4 kW cooling2,309 kWh/yr | 3 | $739 | |
| Braemar NCHV10D1410.5 kW heating10.1 kW cooling2,264 kWh/yr | 2.5 | $724 |
Compare NCHV10D14B with another model
Braemar NCHV10D14B specifications
- Type
- Reverse cycle
- Configuration
- Fixed
- Air distribution
- Ducted or non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 10.60 kW
- Cooling power input
- 2.65 kW
- Rated heating capacity (7 Β°C)
- 11.40 kW
- Heating power input
- 2.85 kW
- EER, full load (tested)
- 4.12
- COP, full load (tested)
- 4.18
- Rated AEER
- 3.95
- Rated ACOP
- 3.95
- Standby power (PIA)
- 10.5 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- 69.1 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Braemar NCHV10D14B zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,113 | 1,201 |
| Coldresidential | residential | 3.5 | 2.0 | 524 | 3,840 |
| Mixedcommercial | commercial | β | β | 1,412 | 613 |
| Mixedresidential | residential | 3.5 | 3.0 | 827 | 1,390 |
| Hotcommercial | commercial | β | β | 3,168 | 136 |
| Hotresidential | residential | 4.0 | 3.5 | 2,386 | 210 |
Part-load test points (20 values)
- h__h2_ext_cap_power_rated
- 3900 W
- c__t1_half_cap_power_rated
- 860 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 1000 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 10500 W
- h__h1_half_cap_heat_cap_rated
- 5700 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_full_cap_power_rated
- 2422.1 W
- c__low_temp_half_cap_power_rated
- 786.0400000000001 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 5300 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_full_cap_cooling_cap_rated
- 11416.199999999999 W
- c__low_temp_half_cap_cooling_cap_rated
- 5708.099999999999 W
Australian GEMS registration details
- Registration number
- AAC7927
- GEMS registration id
- 157019
- Status
- approved, available (self-reported)
- Registration expires
- 3 December 2028
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.4:2012
- MEPS
- 2019
- Product class
- Class 20
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: gree.com. How the derived figures are calculated.