c/kWh
Energy rating (cooling)
4
Heating: 2.5
Annual electricity use
1,076 kWh
373 cooling + 703 heating
Estimated running cost
$344 / year
$29 / month Β· $3,443 over 10 years
Capacity
5 kW cooling
5.3 kW heating

2% less electricity than the median of 240 comparable 5 kW reverse cycle split system registrations (1,093 kWh a year) in the mixed zone. Uses less than 58% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 76% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Carrier 38QAG050N8 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,154$689$6,893
Mixed zone 1,076$344$3,443
Hot zone 1,204$385$3,853

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 5 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling839 kWh/yr4$268
Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling847 kWh/yr4$271
Actron Air WRC-050CS / WRE-050CS5 kW heating5 kW cooling942 kWh/yr4.5$301
Panasonic CU-HZ50DKR / CS-HZ50DKR6 kW heating5 kW cooling949 kWh/yr5$304
Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling949 kWh/yr4$304

Air conditioners similar to the Carrier 38QAG050N8

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Rinnai HONRPX50/HINRPX50M6 kW heating5 kW cooling997 kWh/yr5$319
Haier 1U50PFHRA / AS50PFHRA5.3 kW heating5 kW cooling990 kWh/yr4$317
Daikin RXM50WVMA / FTXM50WVMA6 kW heating5 kW cooling942 kWh/yr5$301
Midea MFEP51VA-W/MFEP51VA-N5.3 kW heating5 kW cooling1,008 kWh/yr4$323
Actron Air WRC-050CS / WRE-050CS5 kW heating5 kW cooling942 kWh/yr4.5$301
Midea MFEZ50VA-W/MFEZ50VA-N6 kW heating5 kW cooling997 kWh/yr5$319
Daikin RXM50AVMA / FTXM50AVMA6 kW heating5 kW cooling937 kWh/yr5$300
Panasonic CU-HZ50DKR / CS-HZ50DKR6 kW heating5 kW cooling949 kWh/yr5$304

Compare 38QAG050N8/42QAG050N8 with another model

Carrier 38QAG050N8 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
5.00 kW
Cooling power input
1.36 kW
Rated heating capacity (7 Β°C)
5.35 kW
Heating power input
1.46 kW
EER, full load (tested)
3.94
COP, full load (tested)
4.12
Rated AEER
3.67
Rated ACOP
3.66
Standby power (PIA)
0.5 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
57.8 dB(A)
Outdoor sound power
65.8 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Carrier 38QAG050N8 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––350594
Coldresidential4.02.02331,921
Mixedcommercial––529303
Mixedresidential4.02.5373703
Hotcommercial––1,36059
Hotresidential4.03.01,10995
Part-load test points (25 values)
c__t1_min_cap_power_rated
480 W
h__h1_min_cap_power_rated
460 W
h__h2_ext_cap_power_rated
1700 W
c__t1_half_cap_power_rated
510 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
540 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2400 W
h__h2_ext_cap_heat_cap_rated
4800 W
h__h1_half_cap_heat_cap_rated
2650 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
320 W
c__t1_min_cap_cooling_cap_rated
2320 W
c__low_temp_full_cap_power_rated
1243.04 W
c__low_temp_half_cap_power_rated
390 W
c__t1_half_cap_cooling_cap_rated
2500 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2300 W
c__low_temp_full_cap_cooling_cap_rated
5385 W
c__low_temp_half_cap_cooling_cap_rated
2640 W

Australian GEMS registration details

Registration number
AAC7707
GEMS registration id
156095
Status
approved, available (self-reported)
Registration expires
13 August 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: midea.com.cn. How the derived figures are calculated.