c/kWh
Energy rating (cooling)
3.5
Heating: 2.5
Annual electricity use
1,936 kWh
695 cooling + 1,241 heating
Estimated running cost
$620 / year
$52 / month Β· $6,195 over 10 years
Capacity
8.6 kW cooling
9.1 kW heating

12% less electricity than the median of 31 comparable 8 kW reverse cycle ducted split system registrations (2,210 kWh a year) in the mixed zone. Uses less than 90% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 52% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Carrier 38QSH090D8S running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,779$1,209$12,093
Mixed zone 1,936$620$6,195
Hot zone 2,080$666$6,656

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 8.6 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Carrier 38QSM080D8S/42QSM080D8S8.3 kW heating7.8 kW cooling1,757 kWh/yr3.5$562

Air conditioners similar to the Carrier 38QSH090D8S

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Fujitsu AOTH30KCTA/ARTH30KHTA10 kW heating8.5 kW cooling1,986 kWh/yr3$636
Fujitsu AOTH30KCTA/ARTH30KMTAP10 kW heating8.5 kW cooling2,000 kWh/yr3$640
TCL TCD85D1HWH-DVO/TCD85D1HWH-DVI10 kW heating8.5 kW cooling2,036 kWh/yr3$652
Daikin RZAV85C2Y1 / FBA85BVMA10 kW heating8.5 kW cooling2,117 kWh/yr2.5$677
Temperzone OSAT 85RLSFH / ISDT 85LY10 kW heating8.5 kW cooling2,162 kWh/yr3$692
Daikin RZAV85CV1 / FBA85BVMA10 kW heating8.5 kW cooling2,114 kWh/yr2.5$676
Hisense AUW-85U4RK1/AUD-85UX4RSH110 kW heating8.5 kW cooling2,268 kWh/yr2.5$726
Samsung Electronics AC090TXAPKG/SA / AC090TNHDKG/SA10 kW heating8.5 kW cooling2,308 kWh/yr2$739

Compare 38QSH090D8S/42QSH090D8S with another model

Carrier 38QSH090D8S specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
8.60 kW
Cooling power input
2.55 kW
Rated heating capacity (7 Β°C)
9.14 kW
Heating power input
2.32 kW
EER, full load (tested)
3.59
COP, full load (tested)
4.39
Rated AEER
3.32
Rated ACOP
3.88
Standby power (PIA)
11.1 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Carrier 38QSH090D8S zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––3091,058
Coldresidential3.52.04383,341
Mixedcommercial––717552
Mixedresidential3.52.56951,241
Hotcommercial––1,771126
Hotresidential4.03.01,886194
Part-load test points (23 values)
c__t1_min_cap_power_rated
650 W
h__h1_min_cap_power_rated
450 W
h__h2_ext_cap_power_rated
3700 W
c__t1_half_cap_power_rated
1280 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1000 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2090 W
h__h2_ext_cap_heat_cap_rated
8900 W
h__h1_half_cap_heat_cap_rated
4680 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
380 W
c__t1_min_cap_cooling_cap_rated
2400 W
c__low_temp_half_cap_power_rated
690 W
c__t1_half_cap_cooling_cap_rated
4000 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2400 W
c__low_temp_half_cap_cooling_cap_rated
4200 W

Australian GEMS registration details

Registration number
AAC10178
GEMS registration id
179582
Status
approved, available (self-reported)
Registration expires
1 August 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 10

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: midea.com.cn. How the derived figures are calculated.