c/kWh
Energy rating (cooling)
3.5
Heating: 2.5
Annual electricity use
1,503 kWh
563 cooling + 940 heating
Estimated running cost
$481 / year
$40 / month Β· $4,810 over 10 years
Capacity
7.1 kW cooling
7.1 kW heating

14% less electricity than the median of 78 comparable 7 kW reverse cycle ducted split system registrations (1,746 kWh a year) in the mixed zone. Uses less than 82% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 64% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Carrier 38QSM070D8S running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,829$905$9,053
Mixed zone 1,503$481$4,810
Hot zone 1,725$552$5,520

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 7.1 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Panasonic U-71PZ4R5 / S-6071PF3E6.8 kW heating6.8 kW cooling1,451 kWh/yr2.5$464

Air conditioners similar to the Carrier 38QSM070D8S

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Panasonic U-71PZ4R5 / S-71PE4R7.1 kW heating7.1 kW cooling1,588 kWh/yr2.5$508
Gree GFH24ACXF-S6DNE3D/O / GFH24ACXF-S6DNE3D/I7.6 kW heating7.1 kW cooling1,598 kWh/yr3$511
TCL TCD71D1HWH-DVO/TCD71D1HWH-DVI7.5 kW heating7.1 kW cooling1,523 kWh/yr3.5$487
Hyundai HYDCTAC71TB7.5 kW heating7.1 kW cooling1,523 kWh/yr3.5$487
Hyundai HYDCTAC71TD7.5 kW heating7.1 kW cooling1,523 kWh/yr3.5$487
Gree GFH24ACXF-S6DNE3D/O / GFH24ACXF-S6DNE3D/I7.6 kW heating7.1 kW cooling1,605 kWh/yr3$514
Braemar KCHB070D1B/KDHB070D1S7.6 kW heating7.1 kW cooling1,598 kWh/yr3$511
Panasonic U-71PZH3R5 / S-71PE4R8 kW heating7.1 kW cooling1,605 kWh/yr3$514

Compare 38QSM070D8S/42QSM070D8S with another model

Carrier 38QSM070D8S specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
7.08 kW
Cooling power input
2.20 kW
Rated heating capacity (7 Β°C)
7.08 kW
Heating power input
1.83 kW
EER, full load (tested)
3.49
COP, full load (tested)
4.40
Rated AEER
3.19
Rated ACOP
3.83
Standby power (PIA)
5.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Carrier 38QSM070D8S zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––456790
Coldresidential3.52.03552,474
Mixedcommercial––684418
Mixedresidential3.52.5563940
Hotcommercial––1,48191
Hotresidential4.03.01,584141
Part-load test points (23 values)
c__t1_min_cap_power_rated
580 W
h__h1_min_cap_power_rated
380 W
h__h2_ext_cap_power_rated
2830 W
c__t1_half_cap_power_rated
1170 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
730 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1760 W
h__h2_ext_cap_heat_cap_rated
7470 W
h__h1_half_cap_heat_cap_rated
3520 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
290 W
c__t1_min_cap_cooling_cap_rated
2650 W
c__low_temp_half_cap_power_rated
630 W
c__t1_half_cap_cooling_cap_rated
3650 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2080 W
c__low_temp_half_cap_cooling_cap_rated
3460 W

Australian GEMS registration details

Registration number
AAC10174
GEMS registration id
179573
Status
approved, available (self-reported)
Registration expires
2 August 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 10

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: midea.com.cn. How the derived figures are calculated.