c/kWh
Energy rating (cooling)
3
Heating: 2.5
Annual electricity use
2,979 kWh
1,115 cooling + 1,864 heating
Estimated running cost
$953 / year
$79 / month Β· $9,533 over 10 years
Capacity
13.6 kW cooling
14.5 kW heating

16% less electricity than the median of 117 comparable 14 kW reverse cycle ducted split system registrations (3,549 kWh a year) in the mixed zone. Uses less than 93% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 36% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Carrier 38QSM140D8S running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,575$1,784$17,840
Mixed zone 2,979$953$9,533
Hot zone 3,574$1,144$11,437

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 13.6 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Panasonic U-125PZ3R8 / S-1014PF3E12.1 kW heating12.1 kW cooling1,681 kWh/yr1.5$538
Brivis AONSR13B1/AINHU13B113.8 kW heating12 kW cooling2,209 kWh/yr4$707
Brivis AONSR15B1/AINHU15B115.7 kW heating13.6 kW cooling2,497 kWh/yr5$799
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling2,556 kWh/yr3.5$818
Rinnai DONSR13B1/DINLR13B113 kW heating12.5 kW cooling2,559 kWh/yr3.5$819

Air conditioners similar to the Carrier 38QSM140D8S

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Brivis AONSR15B1/AINHU15B115.7 kW heating13.6 kW cooling2,497 kWh/yr5$799
Bonaire CRC6960014/CRC696011416 kW heating13.5 kW cooling3,952 kWh/yr2.5$1,265
Panasonic U-140PZ4R5 / S-1014PF3E13.4 kW heating13.4 kW cooling3,008 kWh/yr2.5$963
LG UU140WR3 U30/UMN140M3 N3015.5 kW heating13.8 kW cooling3,842 kWh/yr2.5$1,229
Panasonic U-140PZ4R8 / S-1014PF3E13.4 kW heating13.4 kW cooling3,008 kWh/yr2.5$963
LG UU140WR2 U30/UMN140M3 N3015.5 kW heating13.8 kW cooling4,804 kWh/yr1.5$1,537
Kaden KDI48 / KDI4814 kW heating14 kW cooling2,861 kWh/yr3.5$916

Other Carrier models of similar capacity

ModelStarsEst. cost / yrCompare
Carrier 38QSH140D8S-1/42QSH140D8S-114.3 kW heating13.6 kW cooling2,888 kWh/yr3.5$924

Compare 38QSM140D8S/42QSM140D8S with another model

Carrier 38QSM140D8S specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
13.60 kW
Cooling power input
4.22 kW
Rated heating capacity (7 Β°C)
14.50 kW
Heating power input
3.81 kW
EER, full load (tested)
3.30
COP, full load (tested)
3.81
Rated AEER
3.19
Rated ACOP
3.76
Standby power (PIA)
13.3 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Carrier 38QSM140D8S zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––-3981,515
Coldresidential3.52.07084,867
Mixedcommercial––1,155797
Mixedresidential3.02.51,1151,864
Hotcommercial––3,484176
Hotresidential3.53.53,298276
Part-load test points (25 values)
c__t1_min_cap_power_rated
895 W
h__h1_min_cap_power_rated
586 W
h__h2_ext_cap_power_rated
5319 W
c__t1_half_cap_power_rated
1489 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1398 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3066 W
h__h2_ext_cap_heat_cap_rated
15558 W
h__h1_half_cap_heat_cap_rated
6945 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
510 W
c__t1_min_cap_cooling_cap_rated
3730 W
c__low_temp_full_cap_power_rated
3857.08 W
c__low_temp_half_cap_power_rated
1270 W
c__t1_half_cap_cooling_cap_rated
7000 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3660 W
c__low_temp_full_cap_cooling_cap_rated
14647.199999999999 W
c__low_temp_half_cap_cooling_cap_rated
7609 W

Australian GEMS registration details

Registration number
AAC6783
GEMS registration id
147742
Status
approved, available (self-reported)
Registration expires
20 June 2027
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: midea.com.cn. How the derived figures are calculated.