Australia Β· costs in AUD

Reverse cycle air conditioner
Carrier 38QUM190D8S6-1 Air Conditioner
Carrier 38QUM190D8S6-1 is a 19 kW reverse cycle air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC816805965).
- Energy rating (cooling)
- 3.5
- Heating: 3
- Annual electricity use
- 4,127 kWh
- 1,482 cooling + 2,645 heating
- Estimated running cost
- $1,321 / year
- $110 / month Β· $13,206 over 10 years
- Capacity
- 19 kW cooling
- 21.5 kW heating
19% less electricity than the median of 42 comparable 20 kW reverse cycle registrations (5,102 kWh a year) in the mixed zone. Uses less than 79% of them.
Across all 3,638 air conditioner registrations sold in Australia, it uses less than 22% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Carrier 38QUM190D8S6-1 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 8,459 | $2,707 | $27,069 |
| Mixed zone | 4,127 | $1,321 | $13,206 |
| Hot zone | 4,648 | $1,487 | $14,874 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 19 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Silicon Electronics EMV-V170W/N117 kW heating17 kW cooling3,211 kWh/yr | 3.5 | $1,028 | |
| Smart User SMV-V170W/N117 kW heating17 kW cooling3,211 kWh/yr | 3.5 | $1,028 | |
| Smart User SMV-V170W/N117 kW heating17 kW cooling3,219 kWh/yr | 3.5 | $1,030 | |
| Silicon Electronics EMV-V200W/N120 kW heating18 kW cooling3,622 kWh/yr | 3 | $1,159 | |
| Aux ARV-H180/NR1B-AU21.5 kW heating18.1 kW cooling3,741 kWh/yr | 3.5 | $1,197 |
Air conditioners similar to the Carrier 38QUM190D8S6-1
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Midea MULMI0619B21.5 kW heating19 kW cooling4,127 kWh/yr | 3.5 | $1,321 | |
| Midea MULMI0619C21.5 kW heating19 kW cooling4,127 kWh/yr | 3.5 | $1,321 | |
| Aux ARV-H180/NR1B-AU21.5 kW heating18.1 kW cooling3,741 kWh/yr | 3.5 | $1,197 | |
| Hisense AVW-63HJFAH120 kW heating18.1 kW cooling3,946 kWh/yr | 3 | $1,263 | |
| Silicon Electronics EMV-V200W/N120 kW heating18 kW cooling3,622 kWh/yr | 3 | $1,159 | |
| Smart User SMV-V200W/N120 kW heating18 kW cooling3,622 kWh/yr | 3 | $1,159 | |
| Smart User SMV-V225W/N122.5 kW heating18 kW cooling3,382 kWh/yr | 4 | $1,082 |
Other Carrier models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Carrier 38QUM190D8S621.5 kW heating19 kW cooling4,127 kWh/yr | 3.5 | $1,321 |
Compare 38QUM190D8S6-1 with another model
Carrier 38QUM190D8S6-1 specifications
- Type
- Reverse cycle
- Configuration
- β
- Air distribution
- Non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 19.00 kW
- Cooling power input
- β
- Rated heating capacity (7 Β°C)
- 21.50 kW
- Heating power input
- β
- EER, full load (tested)
- 3.49
- COP, full load (tested)
- 4.24
- Rated AEER
- 3.42
- Rated ACOP
- 4.16
- Standby power (PIA)
- 20.8 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- 71.5 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Carrier 38QUM190D8S6-1 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,581 | 2,280 |
| Coldresidential | residential | 4.0 | 2.0 | 923 | 7,536 |
| Mixedcommercial | commercial | β | β | 2,188 | 1,129 |
| Mixedresidential | residential | 3.5 | 3.0 | 1,482 | 2,645 |
| Hotcommercial | commercial | β | β | 5,295 | 249 |
| Hotresidential | residential | 4.0 | 3.5 | 4,260 | 388 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 888 W
- h__h1_min_cap_power_rated
- 710 W
- h__h2_ext_cap_power_rated
- 6400 W
- c__t1_half_cap_power_rated
- 1676 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 2050 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 3900 W
- h__h2_ext_cap_heat_cap_rated
- 17500 W
- h__h1_half_cap_heat_cap_rated
- 11000 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 715 W
- c__t1_min_cap_cooling_cap_rated
- 5400 W
- c__low_temp_half_cap_power_rated
- 1250 W
- c__t1_half_cap_cooling_cap_rated
- 9550 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 6000 W
- c__low_temp_half_cap_cooling_cap_rated
- 9350 W
Australian GEMS registration details
- Registration number
- AAC816805965
- GEMS registration id
- β
- Status
- approved
- Registration expires
- 14 October 2031
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.4:2012
- MEPS
- 2019
- Product class
- 20
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 1 November 2026; last checked 2 November 2026. Manufacturer: carrierair.com.au. How the derived figures are calculated.