Australia Β· costs in AUD
Reverse cycle split system air conditioner, wall hung
Comfee CASG-XG80/CASN-XG80 Air Conditioner
Comfee CASG-XG80/CASN-XG80 is a 7.9 kW reverse cycle split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC7812).
- Energy rating (cooling)
- 3.5
- Heating: 2.5
- Annual electricity use
- 1,701 kWh
- 635 cooling + 1,066 heating
- Estimated running cost
- $544 / year
- $45 / month Β· $5,443 over 10 years
- Capacity
- 7.9 kW cooling
- 8.2 kW heating
7% less electricity than the median of 125 comparable 8 kW reverse cycle split system registrations (1,834 kWh a year) in the mixed zone. Uses less than 98% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 58% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Comfee CASG-XG80 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 3,328 | $1,065 | $10,650 |
| Mixed zone | 1,701 | $544 | $5,443 |
| Hot zone | 2,055 | $658 | $6,576 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 7.9 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Mdv C-UV-74N8-QC3W / CSV-72N8-QC7W7.7 kW heating7.2 kW cooling1,404 kWh/yr | 4 | $449 | |
| Panasonic U-71PZ4R5 / S-6071PU3E7.1 kW heating7.1 kW cooling1,426 kWh/yr | 3 | $456 | |
| Kogan KASSSAC71HE7.5 kW heating7.1 kW cooling1,433 kWh/yr | 4 | $459 | |
| Kogan KASSSAC71HF7.5 kW heating7.1 kW cooling1,433 kWh/yr | 4 | $459 | |
| Panasonic U-71PZ3R5 / S-6071PU3E7.1 kW heating7.1 kW cooling1,441 kWh/yr | 3 | $461 |
Air conditioners similar to the Comfee CASG-XG80
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Mitsubishi Electric MUZ-GS80VFD2 / MSZ-GS80VFD2 Series9.1 kW heating7.9 kW cooling1,850 kWh/yr | 3 | $592 | |
| Mitsubishi Electric MUZ-GS80VFD2 / MSZ-GS80VFD29.1 kW heating7.9 kW cooling1,850 kWh/yr | 3 | $592 | |
| Midea MFEF80VA-W/MFEF80VA-N8.7 kW heating8 kW cooling1,794 kWh/yr | 3.5 | $574 | |
| Rinnai HONRPX80/HINRPX80M8.7 kW heating8 kW cooling1,794 kWh/yr | 3.5 | $574 | |
| Midea MFEZ80VA-W/MFEZ80VA-N8.7 kW heating8 kW cooling1,794 kWh/yr | 3.5 | $574 | |
| Westinghouse WSD79HWC-E / WSD79HWC-I8.7 kW heating8 kW cooling1,799 kWh/yr | 3.5 | $576 | |
| Carrier Carrier Ambi8.7 kW heating8 kW cooling1,794 kWh/yr | 3.5 | $574 | |
| Actron Air HRC-080DS / HRE-080DS8.7 kW heating8 kW cooling1,794 kWh/yr | 3.5 | $574 |
Compare CASG-XG80/CASN-XG80 with another model
Comfee CASG-XG80 specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 7.90 kW
- Cooling power input
- 2.20 kW
- Rated heating capacity (7 Β°C)
- 8.20 kW
- Heating power input
- 2.28 kW
- EER, full load (tested)
- 3.40
- COP, full load (tested)
- 3.62
- Rated AEER
- 3.59
- Rated ACOP
- 3.59
- Standby power (PIA)
- 1.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 64.6 dB(A)
- Outdoor sound power
- 66.5 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Comfee CASG-XG80 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 692 | 892 |
| Coldresidential | residential | 3.5 | 2.0 | 402 | 2,926 |
| Mixedcommercial | commercial | β | β | 965 | 453 |
| Mixedresidential | residential | 3.5 | 2.5 | 635 | 1,066 |
| Hotcommercial | commercial | β | β | 2,453 | 88 |
| Hotresidential | residential | 3.5 | 3.0 | 1,914 | 141 |
Part-load test points (25 values)
- c__t1_min_cap_power_rated
- 665 W
- h__h1_min_cap_power_rated
- 460 W
- h__h2_ext_cap_power_rated
- 2979 W
- c__t1_half_cap_power_rated
- 780 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 800 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 2380 W
- h__h2_ext_cap_heat_cap_rated
- 7782 W
- h__h1_half_cap_heat_cap_rated
- 4020 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 480 W
- c__t1_min_cap_cooling_cap_rated
- 3100 W
- c__low_temp_full_cap_power_rated
- 2010.8000000000002 W
- c__low_temp_half_cap_power_rated
- 686 W
- c__t1_half_cap_cooling_cap_rated
- 3790 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 3260 W
- c__low_temp_full_cap_cooling_cap_rated
- 8508.3 W
- c__low_temp_half_cap_cooling_cap_rated
- 4165 W
Australian GEMS registration details
- Registration number
- AAC7812
- GEMS registration id
- 157072
- Status
- approved, available (self-reported)
- Registration expires
- 7 October 2028
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.