Australia Β· costs in AUD

Reverse cycle multi-split / vrf air conditioner
Daikin RQYQ20TY1A Air Conditioner
Daikin RQYQ20TY1A is a 56 kW reverse cycle multi-split / vrf air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC7391).
- Energy rating (cooling)
- 2
- Heating: 1
- Annual electricity use
- 19,399 kWh
- 5,692 cooling + 13,707 heating
- Estimated running cost
- $6,208 / year
- $517 / month Β· $62,077 over 10 years
- Capacity
- 56 kW cooling
- 63 kW heating
44% more electricity than the median of 55 comparable 50 kW reverse cycle multi-split / vrf registrations (13,461 kWh a year) in the mixed zone. Uses less than 4% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 3% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Daikin RQYQ20TY1A running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 39,463 | $12,628 | $126,282 |
| Mixed zone | 19,399 | $6,208 | $62,077 |
| Hot zone | 18,433 | $5,899 | $58,986 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 56 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Carrier 38VT018188QTSG50.4 kW heating50.4 kW cooling3,923 kWh/yr | 3.5 | $1,255 | |
| Carrier 38VT020188QTSG56 kW heating56 kW cooling4,381 kWh/yr | 3.5 | $1,402 | |
| Toshiba MMY-MUP1801HT8P-A56 kW heating50.4 kW cooling4,410 kWh/yr | 3 | $1,411 | |
| Toshiba MMY-MUP2001HT8P-A63 kW heating56 kW cooling4,818 kWh/yr | 3 | $1,542 | |
| Hitachi RAS-22FSXNS69 kW heating61.5 kW cooling8,410 kWh/yr | 1 | $2,691 |
Air conditioners similar to the Daikin RQYQ20TY1A
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| LG ARUM201LTE663 kW heating56 kW cooling12,536 kWh/yr | 3 | $4,012 | |
| Samsung Electronics AM200DXVGGH/SA63 kW heating56 kW cooling13,945 kWh/yr | 2.5 | $4,462 | |
| Toshiba MMY-MUP2001HT8P-A63 kW heating56 kW cooling4,818 kWh/yr | 3 | $1,542 | |
| Toshiba MMY-MAP2006FT8P-A56 kW heating56 kW cooling6,648 kWh/yr | 1.5 | $2,127 | |
| Carrier 38VT020188QTSG56 kW heating56 kW cooling4,381 kWh/yr | 3.5 | $1,402 | |
| LG ARUM200LTE563 kW heating56 kW cooling15,540 kWh/yr | 2.5 | $4,973 | |
| Carrier 38VT020188HTSG63 kW heating56 kW cooling4,818 kWh/yr | 3 | $1,542 | |
| Samsung Electronics AM200DXVGGR/SA63 kW heating56 kW cooling13,945 kWh/yr | 2.5 | $4,462 |
Compare RQYQ20TY1A with another model
Daikin RQYQ20TY1A specifications
- Type
- Reverse cycle
- Configuration
- Multi-split / VRF
- Air distribution
- Non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 56.00 kW
- Cooling power input
- 18.80 kW
- Rated heating capacity (7 Β°C)
- 63.00 kW
- Heating power input
- 18.25 kW
- EER, full load (tested)
- 2.97
- COP, full load (tested)
- 3.53
- Rated AEER
- 2.92
- Rated ACOP
- 3.39
- Standby power (PIA)
- 106.4 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R410A
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- Thailand
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Daikin RQYQ20TY1A zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 6,938 | 12,241 |
| Coldresidential | residential | 2.5 | 0.5 | 3,612 | 35,851 |
| Mixedcommercial | commercial | β | β | 9,092 | 6,446 |
| Mixedresidential | residential | 2.0 | 1.0 | 5,692 | 13,707 |
| Hotcommercial | commercial | β | β | 20,863 | 1,499 |
| Hotresidential | residential | 2.5 | 1.0 | 16,141 | 2,292 |
Part-load test points (20 values)
- h__h2_ext_cap_power_rated
- 25010 W
- c__t1_half_cap_power_rated
- 5812 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 11321 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 48484 W
- h__h1_half_cap_heat_cap_rated
- 31500 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_full_cap_power_rated
- 17183.2 W
- c__low_temp_half_cap_power_rated
- 4772 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 28000 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_full_cap_cooling_cap_rated
- 60312 W
- c__low_temp_half_cap_cooling_cap_rated
- 28000 W
Australian GEMS registration details
- Registration number
- AAC7391
- GEMS registration id
- 153017
- Status
- approved, available (self-reported)
- Registration expires
- 29 March 2028
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.4:2012
- MEPS
- 2019
- Product class
- Class 21
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: daikin.com.au. How the derived figures are calculated.