c/kWh
Energy rating (cooling)
2.5
Heating: 2.5
Annual electricity use
1,552 kWh
599 cooling + 953 heating
Estimated running cost
$497 / year
$41 / month Β· $4,966 over 10 years
Capacity
6 kW cooling
7.2 kW heating

16% more electricity than the median of 104 comparable 6 kW reverse cycle split system registrations (1,340 kWh a year) in the mixed zone. Uses less than 7% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 62% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Daikin RXJ60TVMA running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,872$919$9,190
Mixed zone 1,552$497$4,966
Hot zone 1,910$611$6,112

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 6 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Hyundai HYSSSAC53T*5.3 kW heating5.3 kW cooling1,022 kWh/yr4$327
Braemar TCHV05T1S/TSHV05T1S5.3 kW heating5.3 kW cooling1,022 kWh/yr4$327
Hyundai HYSSSAC53TA5.3 kW heating5.3 kW cooling1,022 kWh/yr4$327
TCL TAC-VX18HSV/UD5.3 kW heating5.3 kW cooling1,022 kWh/yr4$327
TCL TAC-VX18HSV/U*5.3 kW heating5.3 kW cooling1,022 kWh/yr4$327

Air conditioners similar to the Daikin RXJ60TVMA

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Midea MFEP60VB-W/MFEP60VB-N6.6 kW heating6 kW cooling1,203 kWh/yr4.5$385
Mitsubishi Electric MUZ-AP60VGD2/MSZ-AP60VGKD26.8 kW heating6 kW cooling1,274 kWh/yr4$408
Actron Air WRC-060DS / WRE-060DS6.6 kW heating6 kW cooling1,203 kWh/yr4.5$385
Hitachi RAC-VJ60PHAT/RAK-VJ60PHAT7 kW heating6 kW cooling1,254 kWh/yr4$401
Mitsubishi Electric MUZ-AP60VGD2/MSZ-AP60VGD26.8 kW heating6 kW cooling1,274 kWh/yr4$408
Rinnai HSNRP60B6.5 kW heating6 kW cooling1,290 kWh/yr4$413
Rinnai HONRPX60/HINRPX60M6.5 kW heating6 kW cooling1,177 kWh/yr4.5$377
Midea MFEZ60VA-W/MFEZ60VA-N6.5 kW heating6 kW cooling1,177 kWh/yr4.5$377

Compare RXJ60TVMA / FTXJ60TVMAW with another model

Daikin RXJ60TVMA specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
6.00 kW
Cooling power input
1.83 kW
Rated heating capacity (7 Β°C)
7.20 kW
Heating power input
1.88 kW
EER, full load (tested)
3.30
COP, full load (tested)
3.84
Rated AEER
3.26
Rated ACOP
3.81
Standby power (PIA)
3.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
64 dB(A)
Outdoor sound power
61 dB(A)
Demand response (AS/NZS 4755)
Yes (requires additional part)
Dimensions (WΓ—HΓ—D)
200 Γ— 990 Γ— 465 mm
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Daikin RXJ60TVMA zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––845803
Coldresidential2.52.03812,491
Mixedcommercial––1,065426
Mixedresidential2.52.5599953
Hotcommercial––2,37790
Hotresidential2.53.01,769141
Part-load test points (16 values)
h__h2_ext_cap_power_rated
2220 W
c__t1_half_cap_power_rated
680 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
730 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
7000 W
h__h1_half_cap_heat_cap_rated
3600 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
3000 W
c__low_temp_have_half_cap_results
No

Other model numbers on registration AAC10091

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC10091
GEMS registration id
178503
Status
approved, available (self-reported)
Registration expires
27 April 2031
Registered for sale in
Australia, New Zealand
Family
RXJ60TVMA / FTXJ60TVMA*
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: daikin.com.au. How the derived figures are calculated.