c/kWh
Energy rating (cooling)
3
Heating: 3
Annual electricity use
2,230 kWh
819 cooling + 1,411 heating
Estimated running cost
$714 / year
$59 / month Β· $7,136 over 10 years
Capacity
10 kW cooling
12 kW heating

8% less electricity than the median of 129 comparable 10 kW reverse cycle ducted split system registrations (2,429 kWh a year) in the mixed zone. Uses less than 82% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 47% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Daikin RZAV100F2V1 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,305$1,378$13,776
Mixed zone 2,230$714$7,136
Hot zone 2,540$813$8,128

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 10 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Panasonic U-100PZ4R8 / S-100PE4*10 kW heating10 kW cooling1,449 kWh/yr2.5$464
Panasonic U-100PZ4R8 / S-100PE4RN10 kW heating10 kW cooling1,449 kWh/yr2.5$464
Brivis AONSR13B1/AINHU11B111.3 kW heating10.3 kW cooling1,881 kWh/yr4.5$602
Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling1,884 kWh/yr3.5$603
Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling1,936 kWh/yr3.5$620

Air conditioners similar to the Daikin RZAV100F2V1

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Mitsubishi Electric PUZ-ZM100VKA2-A/PEA-M100HAA211.2 kW heating10 kW cooling2,314 kWh/yr2.5$740
Pioneer International VPC-36A1/CPE-36A110 kW heating10 kW cooling2,265 kWh/yr3$725
Panasonic U-100PZ4R8 / S-100PE4R10 kW heating10 kW cooling1,449 kWh/yr2.5$464
Toshiba RAV-GP1101AT8P-A/RAV-GM1101BTP-A11.2 kW heating10 kW cooling2,306 kWh/yr3.5$738
Pioneer International VPC-36A110 kW heating10 kW cooling2,265 kWh/yr3$725
Midea UCMI105OB/DUCMI105IHB11 kW heating10 kW cooling2,120 kWh/yr4$678
Panasonic U-100PZ4R8 / S-100PE4*10 kW heating10 kW cooling1,449 kWh/yr2.5$464
Mitsubishi Electric PUZ-ZM100VKA2-A/PEA-M100HAA11.2 kW heating10 kW cooling2,314 kWh/yr2.5$740

Compare RZAV100F2V1 / FBA100BVMA with another model

Daikin RZAV100F2V1 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
10.00 kW
Cooling power input
2.79 kW
Rated heating capacity (7 Β°C)
12.00 kW
Heating power input
2.92 kW
EER, full load (tested)
3.38
COP, full load (tested)
4.08
Rated AEER
3.52
Rated ACOP
4.04
Standby power (PIA)
14.7 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
68 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Daikin RZAV100F2V1 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––8831,179
Coldresidential3.52.55213,784
Mixedcommercial––1,215615
Mixedresidential3.03.08191,411
Hotcommercial––2,876142
Hotresidential4.04.02,323217
Part-load test points (25 values)
c__t1_min_cap_power_rated
520 W
h__h1_min_cap_power_rated
600 W
h__h2_ext_cap_power_rated
3438 W
c__t1_half_cap_power_rated
1031 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1093 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3500 W
h__h2_ext_cap_heat_cap_rated
11200 W
h__h1_half_cap_heat_cap_rated
6100 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
411 W
c__t1_min_cap_cooling_cap_rated
2900 W
c__low_temp_full_cap_power_rated
2550.06 W
c__low_temp_half_cap_power_rated
753 W
c__t1_half_cap_cooling_cap_rated
5100 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3100 W
c__low_temp_full_cap_cooling_cap_rated
10770 W
c__low_temp_half_cap_cooling_cap_rated
5100 W

Australian GEMS registration details

Registration number
AAC6494
GEMS registration id
144585
Status
approved, available (self-reported)
Registration expires
24 February 2027
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11