c/kWh
Energy rating (cooling)
0
Heating: 0
Annual electricity use
3,029 kWh
1,325 cooling + 1,704 heating
Estimated running cost
$969 / year
$81 / month Β· $9,693 over 10 years
Capacity
4.1 kW cooling
3.3 kW heating

19% more electricity than the median of 22 comparable 3.5 kW reverse cycle portable registrations (2,538 kWh a year) in the mixed zone. Uses less than 0% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 35% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Excelair EPA58041RWB running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,370$1,398$13,984
Mixed zone 3,029$969$9,693
Hot zone 3,910$1,251$12,512

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 4.1 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Hyundai HY13KSPACPD2.8 kW heating3.8 kW cooling2,673 kWh/yr0$855
Hyundai HY13KSPACP*2.8 kW heating3.8 kW cooling2,673 kWh/yr0$855
Ausclimate Ausclimate 14K PAC2.9 kW heating4.2 kW cooling2,837 kWh/yr0$908
Ausclimate ACPAC2402.9 kW heating4.2 kW cooling2,837 kWh/yr0$908
Goldair GPPAC4103.2 kW heating4.1 kW cooling2,854 kWh/yr0$913

Air conditioners similar to the Excelair EPA58041RWB

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Alfordson PAC-14-H3.3 kW heating4.1 kW cooling2,988 kWh/yr0$956
Alfordson A-PAC-14-CLT-H3.3 kW heating4.1 kW cooling2,988 kWh/yr0$956
Goldair 4.1kW Hot & Cold Portable Air Conditioner3.2 kW heating4.1 kW cooling2,854 kWh/yr0$913
Goldair PAC13493.2 kW heating4.1 kW cooling2,854 kWh/yr0$913
Bonaire PRC60001413.1 kW heating4 kW cooling2,874 kWh/yr0$920
Ausclimate Ausclimate 14K PAC2.9 kW heating4.2 kW cooling2,837 kWh/yr0$908
Ausclimate PAC11312.9 kW heating4.2 kW cooling2,837 kWh/yr0$908
TECO TPO42HVWAH3.9 kW heating4.2 kW cooling2,983 kWh/yr0$955

Compare EPA58041RWB with another model

Excelair EPA58041RWB specifications

Type
Reverse cycle
Configuration
Portable
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
4.10 kW
Cooling power input
1.58 kW
Rated heating capacity (7 Β°C)
3.30 kW
Heating power input
1.32 kW
EER, full load (tested)
2.61
COP, full load (tested)
2.50
Rated AEER
2.60
Rated ACOP
2.50
Standby power (PIA)
–
Compressor
Fixed speed
Refrigerant
R290
Power supply
Single phase
Indoor sound power
62.9 dB(A)
Outdoor sound power
–
Demand response (AS/NZS 4755)
–
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Excelair EPA58041RWB zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldresidential0.00.08593,511
Mixedresidential0.00.01,3251,704
Hotresidential0.00.03,544366

Australian GEMS registration details

Registration number
AAC8397
GEMS registration id
163442
Status
approved, available (self-reported)
Registration expires
13 August 2029
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[Unitary Single-Duct] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.5:2015
MEPS
2019
Product class
Class 4

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.