Reverse cycle multi-split / vrf air conditioner
Fujitsu AJT054LCLCH Air Conditioner
Fujitsu AJT054LCLCH is a 15.1 kW reverse cycle multi-split / vrf air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC7481).
- Energy rating (cooling)
- 2.5
- Heating: 2
- Annual electricity use
- 3,769 kWh
- 1,447 cooling + 2,322 heating
- Estimated running cost
- $1,206 / year
- $101 / month Β· $12,061 over 10 years
- Capacity
- 15.1 kW cooling
- 15.1 kW heating
3% less electricity than the median of 30 comparable 16 kW reverse cycle multi-split / vrf registrations (3,899 kWh a year) in the mixed zone. Uses less than 67% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 26% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Fujitsu AJT054LCLCH running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 7,717 | $2,469 | $24,694 |
| Mixed zone | 3,769 | $1,206 | $12,061 |
| Hot zone | 4,369 | $1,398 | $13,981 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 15.1 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Smart User SMV-V180W/N119 kW heating15.5 kW cooling3,113 kWh/yr | 3.5 | $996 | |
| Toshiba MCY-MHP0504HS-A16 kW heating14 kW cooling3,190 kWh/yr | 3 | $1,021 | |
| Carrier 38VS005181HCSG16 kW heating14 kW cooling3,190 kWh/yr | 3 | $1,021 | |
| Ers Tech ERS-AC24KWH19.5 kW heating15.5 kW cooling3,193 kWh/yr | 3.5 | $1,022 | |
| Hisense AVW-48HJFAH116 kW heating14 kW cooling3,214 kWh/yr | 3.5 | $1,028 |
Air conditioners similar to the Fujitsu AJT054LCLCH
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Carrier 38VS006181HCSG18 kW heating15.5 kW cooling3,635 kWh/yr | 3 | $1,163 | |
| Metro Heating & Cooling MHC-AC24KWH21 kW heating15.5 kW cooling3,683 kWh/yr | 3.5 | $1,179 | |
| Hisense AVW-54HJFAH117 kW heating15.5 kW cooling3,586 kWh/yr | 3 | $1,148 | |
| Ers Tech ERS-AC24KWH19.5 kW heating15.5 kW cooling3,193 kWh/yr | 3.5 | $1,022 | |
| Smart User SMV-V180W/N119 kW heating15.5 kW cooling3,113 kWh/yr | 3.5 | $996 | |
| Spt AV210C-921 kW heating15.5 kW cooling3,640 kWh/yr | 3.5 | $1,165 | |
| Toshiba MCY-MHP0604HS-A18 kW heating15.5 kW cooling3,635 kWh/yr | 3 | $1,163 | |
| Midea MDV-V200WN1(AU)21 kW heating15.5 kW cooling3,823 kWh/yr | 4 | $1,223 |
Compare AJT054LCLCH with another model
Fujitsu AJT054LCLCH specifications
- Type
- Reverse cycle
- Configuration
- Multi-split / VRF
- Air distribution
- Non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 15.10 kW
- Cooling power input
- 4.73 kW
- Rated heating capacity (7 Β°C)
- 15.10 kW
- Heating power input
- 3.65 kW
- EER, full load (tested)
- 3.24
- COP, full load (tested)
- 4.20
- Rated AEER
- 3.12
- Rated ACOP
- 4.01
- Standby power (PIA)
- 33.8 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R410A
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- 68.7 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Fujitsu AJT054LCLCH zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,858 | 2,027 |
| Coldresidential | residential | 2.5 | 1.0 | 918 | 6,799 |
| Mixedcommercial | commercial | β | β | 2,365 | 1,019 |
| Mixedresidential | residential | 2.5 | 2.0 | 1,447 | 2,322 |
| Hotcommercial | commercial | β | β | 5,297 | 220 |
| Hotresidential | residential | 3.0 | 3.5 | 4,043 | 326 |
Part-load test points (20 values)
- h__h2_ext_cap_power_rated
- 4100 W
- c__t1_half_cap_power_rated
- 1370 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 1320 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 9800 W
- h__h1_half_cap_heat_cap_rated
- 7550 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_full_cap_power_rated
- 4323.22 W
- c__low_temp_half_cap_power_rated
- 1252.18 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 7550 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_full_cap_cooling_cap_rated
- 16262.699999999999 W
- c__low_temp_half_cap_cooling_cap_rated
- 8131.349999999999 W
Australian GEMS registration details
- Registration number
- AAC7481
- GEMS registration id
- 154170
- Status
- approved, available (self-reported)
- Registration expires
- 9 May 2028
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.4:2012
- MEPS
- 2019
- Product class
- Class 20
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: fujitsugeneral.com.au. How the derived figures are calculated.