c/kWh
Energy rating (cooling)
1.5
Heating: 1
Annual electricity use
1,267 kWh
496 cooling + 771 heating
Estimated running cost
$405 / year
$34 / month Β· $4,054 over 10 years
Capacity
3.9 kW cooling
3.6 kW heating

2% more electricity than the median of 16 comparable 3.5 kW reverse cycle window / wall registrations (1,243 kWh a year) in the mixed zone. Uses less than 0% of them.

Across all 3,638 air conditioner registrations sold in Australia, it uses less than 69% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Gree GJH12AG-K6NRND6A running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,324$744$7,437
Mixed zone 1,267$405$4,054
Hot zone 1,579$505$5,053

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 3.9 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Midea MWFI36H3.5 kW heating3.6 kW cooling1,002 kWh/yr2.5$321

Air conditioners similar to the Gree GJH12AG-K6NRND6A

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Kelvinator KWH39HRF3.6 kW heating3.9 kW cooling1,267 kWh/yr1.5$405
Westinghouse WWH39HWA3.6 kW heating3.9 kW cooling1,267 kWh/yr1.5$405
TECO TWW40HFWDG3.6 kW heating3.9 kW cooling1,267 kWh/yr1.5$405
Kaden KW123.6 kW heating3.9 kW cooling1,267 kWh/yr1.5$405
Midea MWFF39H3.5 kW heating3.9 kW cooling1,230 kWh/yr2$394
Westinghouse WWH39HWC3.5 kW heating3.9 kW cooling1,230 kWh/yr2$394
Heller HWA13R3.6 kW heating4.1 kW cooling1,235 kWh/yr1.5$395
Midea MWFI36H3.5 kW heating3.6 kW cooling1,002 kWh/yr2.5$321

Compare GJH12AG-K6NRND6A with another model

Gree GJH12AG-K6NRND6A specifications

Type
Reverse cycle
Configuration
Window / wall
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
3.90 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
3.60 kW
Heating power input
–
EER, full load (tested)
3.29
COP, full load (tested)
3.46
Rated AEER
3.28
Rated ACOP
3.37
Standby power (PIA)
2.2 W
Compressor
Fixed speed
Refrigerant
R32
Power supply
Single phase
Indoor sound power
60.6 dB(A)
Outdoor sound power
69.1 dB(A)
Demand response (AS/NZS 4755)
No
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Gree GJH12AG-K6NRND6A zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––760635
Coldresidential1.50.53281,996
Mixedcommercial––936335
Mixedresidential1.51.0496771
Hotcommercial––2,02270
Hotresidential1.51.01,467112
Part-load test points (6 values)
h__h2_full_cap_power_rated
910 W
h__h3_have_full_cap_results
No
h__h2_full_cap_heat_cap_rated
2300 W
c__low_temp_full_cap_power_rated
1090 W
c__low_temp_have_full_cap_results
Yes
c__low_temp_full_cap_cooling_cap_rated
4250 W

Other model numbers on registration AAC8639

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC8639
GEMS registration id
–
Status
approved
Registration expires
31 March 2030
Registered for sale in
Australia, New Zealand
Family
GJH12AG-K6NRNR1A
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
5

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.