c/kWh
Energy rating (cooling)
2.5
Heating: 2.5
Annual electricity use
7,806 kWh
3,138 cooling + 4,668 heating
Estimated running cost
$2,498 / year
$208 / month Β· $24,979 over 10 years
Capacity
33.5 kW cooling
33.5 kW heating

8% less electricity than the median of 5 comparable 35 kW reverse cycle ducted multi-split / vrf registrations (8,530 kWh a year) in the mixed zone. Uses less than 60% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 10% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Gree GMV-335WM running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 14,915$4,773$47,728
Mixed zone 7,806$2,498$24,979
Hot zone 9,569$3,062$30,621

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners similar to the Gree GMV-335WM

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Panasonic U-12ME2R837.5 kW heating33.5 kW cooling8,530 kWh/yr3$2,730
Braemar MCHX335D319B33.5 kW heating33.5 kW cooling7,806 kWh/yr2.5$2,498
Panasonic U-12ME2R8E37.5 kW heating33.5 kW cooling8,530 kWh/yr3$2,730
Braemar MCRX335D319B33.5 kW heating33.5 kW cooling8,831 kWh/yr1.5$2,826
Haier AV12IMAURA35 kW heating33.5 kW cooling10,236 kWh/yr2$3,276

Compare GMV-335WM/C-X(A) with another model

Gree GMV-335WM specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
33.50 kW
Cooling power input
8.86 kW
Rated heating capacity (7 Β°C)
33.50 kW
Heating power input
8.44 kW
EER, full load (tested)
3.78
COP, full load (tested)
3.97
Rated AEER
3.68
Rated ACOP
3.85
Standby power (PIA)
75.3 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Gree GMV-335WM zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––4,2664,091
Coldresidential2.51.52,04512,870
Mixedcommercial––5,3312,118
Mixedresidential2.52.53,1384,668
Hotcommercial––11,665535
Hotresidential3.03.08,771798
Part-load test points (20 values)
h__h2_ext_cap_power_rated
11430 W
c__t1_half_cap_power_rated
3280 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
3340 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
27820 W
h__h1_half_cap_heat_cap_rated
16750 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
8098.04 W
c__low_temp_half_cap_power_rated
2997.92 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
16750 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
36079.5 W
c__low_temp_half_cap_cooling_cap_rated
18039.75 W

Australian GEMS registration details

Registration number
AAC6432
GEMS registration id
144339
Status
approved, available (self-reported)
Registration expires
2 February 2027
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 20

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.