c/kWh
Energy rating (cooling)
3
Heating: 2.5
Annual electricity use
1,764 kWh
620 cooling + 1,144 heating
Estimated running cost
$564 / year
$47 / month Β· $5,645 over 10 years
Capacity
7.2 kW cooling
8.6 kW heating

1% more electricity than the median of 78 comparable 7 kW reverse cycle ducted split system registrations (1,746 kWh a year) in the mixed zone. Uses less than 41% of them.

Across all 3,681 air conditioner registrations sold in Australia, it uses less than 55% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Hitachi running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,742$1,197$11,974
Mixed zone 1,764$564$5,645
Hot zone 1,929$617$6,173

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 7.2 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Panasonic U-71PZ4R5 / S-6071PF3E6.8 kW heating6.8 kW cooling1,451 kWh/yr2.5$464
Aurora AU-BS24HR-2A-O / AU-LCF24-2A-I7.5 kW heating7.3 kW cooling1,463 kWh/yr3.5$468
Rinnai DONSR07B1/DINLR07B17.5 kW heating7.3 kW cooling1,463 kWh/yr3.5$468
Actron Air LRC-071DS / LRE-071DS7.5 kW heating7.3 kW cooling1,464 kWh/yr4$468
Midea UCMI70OC/DUCMI70IC7.5 kW heating7.3 kW cooling1,464 kWh/yr4$468

Air conditioners similar to the Hitachi

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Midea UCMI70OC/DUCMI70IC7.5 kW heating7.3 kW cooling1,464 kWh/yr4$468
Actron Air LRC-071DS / LRE-071DS7.5 kW heating7.3 kW cooling1,464 kWh/yr4$468
Kaden KDI-7.07.5 kW heating7.3 kW cooling1,464 kWh/yr4$468
Actron Air LRC-071CS / LRE-071CS7.7 kW heating7.3 kW cooling1,479 kWh/yr3.5$473
Carrier 38QSP070N8/42QSP070N87.5 kW heating7.3 kW cooling1,464 kWh/yr4$468
Aurora AU-BS24HR-2A-O / AU-LCF24-2A-I7.5 kW heating7.3 kW cooling1,463 kWh/yr3.5$468
Rinnai DONSR07B1LA/DINLR07B1A7.5 kW heating7.3 kW cooling1,464 kWh/yr4$468
Rinnai DONSR07B1/DINLR07B17.5 kW heating7.3 kW cooling1,463 kWh/yr3.5$468

Compare PAS-3.0UFASNQ1 / PPIH-3.0UFA1NQ with another model

Hitachi specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
7.20 kW
Cooling power input
1.97 kW
Rated heating capacity (7 Β°C)
8.60 kW
Heating power input
2.07 kW
EER, full load (tested)
3.71
COP, full load (tested)
4.17
Rated AEER
3.60
Rated ACOP
4.09
Standby power (PIA)
9.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Hitachi zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––8321,005
Coldresidential3.01.53943,348
Mixedcommercial––1,054463
Mixedresidential3.02.56201,144
Hotcommercial––2,36097
Hotresidential3.54.01,780149
Part-load test points (20 values)
h__h2_ext_cap_power_rated
1700 W
c__t1_half_cap_power_rated
640 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
700 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
5700 W
h__h1_half_cap_heat_cap_rated
4400 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
1800.5800000000002 W
c__low_temp_half_cap_power_rated
584.96 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
3600 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
7754.4 W
c__low_temp_half_cap_cooling_cap_rated
3877.2 W

Australian GEMS registration details

Registration number
AAC7959
GEMS registration id
156563
Status
approved, available (self-reported)
Registration expires
11 December 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 10

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: temperzone.com. How the derived figures are calculated.