c/kWh
Energy rating (cooling)
3.5
Heating: 2.5
Annual electricity use
1,086 kWh
393 cooling + 693 heating
Estimated running cost
$348 / year
$29 / month Β· $3,475 over 10 years
Capacity
5 kW cooling
5.3 kW heating

1% less electricity than the median of 240 comparable 5 kW reverse cycle split system registrations (1,093 kWh a year) in the mixed zone. Uses less than 53% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 75% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Hitachi RAC-DJ50PHAT running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,091$669$6,691
Mixed zone 1,086$348$3,475
Hot zone 1,273$407$4,074

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 5 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling839 kWh/yr4$268
Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling847 kWh/yr4$271
Actron Air WRC-050CS / WRE-050CS5 kW heating5 kW cooling942 kWh/yr4.5$301
Panasonic CU-HZ50DKR / CS-HZ50DKR6 kW heating5 kW cooling949 kWh/yr5$304
Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling949 kWh/yr4$304

Air conditioners similar to the Hitachi RAC-DJ50PHAT

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Rinnai HONRPX50/HINRPX50M6 kW heating5 kW cooling997 kWh/yr5$319
Haier 1U50PFHRA / AS50PFHRA5.3 kW heating5 kW cooling990 kWh/yr4$317
Daikin RXM50WVMA / FTXM50WVMA6 kW heating5 kW cooling942 kWh/yr5$301
Midea MFEP51VA-W/MFEP51VA-N5.3 kW heating5 kW cooling1,008 kWh/yr4$323
Actron Air WRC-050CS / WRE-050CS5 kW heating5 kW cooling942 kWh/yr4.5$301
Midea MFEZ50VA-W/MFEZ50VA-N6 kW heating5 kW cooling997 kWh/yr5$319
Daikin RXM50AVMA / FTXM50AVMA6 kW heating5 kW cooling937 kWh/yr5$300
Panasonic CU-HZ50DKR / CS-HZ50DKR6 kW heating5 kW cooling949 kWh/yr5$304

Compare RAC-DJ50PHAT/RAK-DJ50PHAT with another model

Hitachi RAC-DJ50PHAT specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
5.00 kW
Cooling power input
1.42 kW
Rated heating capacity (7 Β°C)
5.30 kW
Heating power input
1.42 kW
EER, full load (tested)
3.58
COP, full load (tested)
3.78
Rated AEER
3.52
Rated ACOP
3.73
Standby power (PIA)
1.6 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
61 dB(A)
Outdoor sound power
63 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Hitachi RAC-DJ50PHAT zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––428586
Coldresidential4.02.02471,844
Mixedcommercial––592306
Mixedresidential3.52.5393693
Hotcommercial––1,49163
Hotresidential4.03.01,17499
Part-load test points (23 values)
c__t1_min_cap_power_rated
290 W
h__h2_ext_cap_power_rated
1900 W
c__t1_half_cap_power_rated
500 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
520 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
5300 W
h__h1_half_cap_heat_cap_rated
2650 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
221 W
c__t1_min_cap_cooling_cap_rated
1450 W
c__low_temp_full_cap_power_rated
1293.31 W
c__low_temp_half_cap_power_rated
410 W
c__t1_half_cap_cooling_cap_rated
2500 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
1650 W
c__low_temp_full_cap_cooling_cap_rated
5385 W
c__low_temp_half_cap_cooling_cap_rated
2650 W

Australian GEMS registration details

Registration number
AAC7015
GEMS registration id
150074
Status
approved, available (self-reported)
Registration expires
19 September 2027
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: temperzone.com. How the derived figures are calculated.