Australia Β· costs in AUD

Reverse cycle split system air conditioner, wall hung
Hitachi RAC-DJ60PHAT/RAK-DJ60PHAT Air Conditioner
Hitachi RAC-DJ60PHAT/RAK-DJ60PHAT is a 6 kW reverse cycle split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC7259).
A newer registration of this model exists: AAC7473.
- Energy rating (cooling)
- 3.5
- Heating: 2.5
- Annual electricity use
- 1,411 kWh
- 479 cooling + 932 heating
- Estimated running cost
- $452 / year
- $38 / month Β· $4,515 over 10 years
- Capacity
- 6 kW cooling
- 7 kW heating
5% more electricity than the median of 104 comparable 6 kW reverse cycle split system registrations (1,340 kWh a year) in the mixed zone. Uses less than 34% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 66% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Hitachi RAC-DJ60PHAT running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 2,946 | $943 | $9,427 |
| Mixed zone | 1,411 | $452 | $4,515 |
| Hot zone | 1,558 | $499 | $4,986 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 6 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Braemar TCHV05T1S/TSHV05T1S5.3 kW heating5.3 kW cooling1,022 kWh/yr | 4 | $327 | |
| TCL TAC-18CHSD/VEIH5.3 kW heating5.3 kW cooling1,022 kWh/yr | 4 | $327 | |
| TCL TAC-VX18HSV/U*5.3 kW heating5.3 kW cooling1,022 kWh/yr | 4 | $327 | |
| Hyundai HYSSSAC53TC5.3 kW heating5.3 kW cooling1,022 kWh/yr | 4 | $327 | |
| Hyundai HYSSSAC53TD5.3 kW heating5.3 kW cooling1,022 kWh/yr | 4 | $327 |
Air conditioners similar to the Hitachi RAC-DJ60PHAT
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RXM60AVMA / FTXM60AVMA7.2 kW heating6 kW cooling1,205 kWh/yr | 4.5 | $386 | |
| Daikin RXM60WVMA / FTXM60WVMA7.2 kW heating6 kW cooling1,213 kWh/yr | 4.5 | $388 | |
| Midea MFEZ60VA-W/MFEZ60VA-N6.5 kW heating6 kW cooling1,177 kWh/yr | 4.5 | $377 | |
| Mitsubishi Electric MUZ-AP60VG2/MSZ-AP60VGKD26.8 kW heating6 kW cooling1,274 kWh/yr | 4 | $408 | |
| Actron Air WRC-060DS / WRE-060DS6.6 kW heating6 kW cooling1,203 kWh/yr | 4.5 | $385 | |
| Mitsubishi Electric MUZ-AP60VGD2/MSZ-AP60VGD26.8 kW heating6 kW cooling1,274 kWh/yr | 4 | $408 | |
| Rinnai HONRPX60/HINRPX60M6.5 kW heating6 kW cooling1,177 kWh/yr | 4.5 | $377 | |
| Midea MFEP60VB-W/MFEP60VB-N6.6 kW heating6 kW cooling1,203 kWh/yr | 4.5 | $385 |
Compare RAC-DJ60PHAT/RAK-DJ60PHAT with another model
Hitachi RAC-DJ60PHAT specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 6.00 kW
- Cooling power input
- 1.80 kW
- Rated heating capacity (7 Β°C)
- 7.00 kW
- Heating power input
- 1.83 kW
- EER, full load (tested)
- 3.42
- COP, full load (tested)
- 3.70
- Rated AEER
- 3.32
- Rated ACOP
- 3.81
- Standby power (PIA)
- 2.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 62 dB(A)
- Outdoor sound power
- 64 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Hitachi RAC-DJ60PHAT zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 540 | 818 |
| Coldresidential | residential | 4.0 | 1.5 | 298 | 2,648 |
| Mixedcommercial | commercial | β | β | 728 | 408 |
| Mixedresidential | residential | 3.5 | 2.5 | 479 | 932 |
| Hotcommercial | commercial | β | β | 1,821 | 82 |
| Hotresidential | residential | 3.5 | 3.0 | 1,428 | 130 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 252.4 W
- h__h2_ext_cap_power_rated
- 2537.3 W
- c__t1_half_cap_power_rated
- 588.6 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 700 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 5976.7 W
- h__h1_half_cap_heat_cap_rated
- 3600 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 235.7 W
- c__t1_min_cap_cooling_cap_rated
- 1073.3 W
- c__low_temp_full_cap_power_rated
- 1645.2 W
- c__low_temp_half_cap_power_rated
- 484.4 W
- c__t1_half_cap_cooling_cap_rated
- 3000 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 1866.8 W
- c__low_temp_full_cap_cooling_cap_rated
- 6462 W
- c__low_temp_half_cap_cooling_cap_rated
- 3180 W
Related Hitachi model numbers starting with RACDJ60PHATRAKDJ60PHAT
1 model numbers on 1 other registration. Variants registered separately can carry different star ratings and energy figures; check the registration number on the label.
| Model | Registration | Stars | kWh / yr | Registration expires |
|---|---|---|---|---|
| RAC-DJ60PHAT/RAK-DJ60PHAT | AAC7473 | 3.5 | 1,388 | 7 May 2028 |
Australian GEMS registration details
- Registration number
- AAC7259
- GEMS registration id
- 152557
- Status
- approved, unavailable (self-reported)
- Registration expires
- 15 February 2028
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: temperzone.com. How the derived figures are calculated.