Australia Β· costs in AUD

Reverse cycle split system air conditioner, wall hung
Hitachi RAC-P35YHAB/RAS-P35YHAB Air Conditioner
Hitachi RAC-P35YHAB/RAS-P35YHAB is a 3.5 kW reverse cycle split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC6361).
- Energy rating (cooling)
- 5
- Heating: 3.5
- Annual electricity use
- 660 kWh
- 212 cooling + 448 heating
- Estimated running cost
- $211 / year
- $18 / month Β· $2,112 over 10 years
- Capacity
- 3.5 kW cooling
- 4.3 kW heating
7% less electricity than the median of 196 comparable 3.5 kW reverse cycle split system registrations (709 kWh a year) in the mixed zone. Uses less than 79% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 88% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Hitachi RAC-P35YHAB running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 1,338 | $428 | $4,282 |
| Mixed zone | 660 | $211 | $2,112 |
| Hot zone | 685 | $219 | $2,192 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 3.5 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Midea MFEP35VA-W/MFEP35VA-N3.6 kW heating3.5 kW cooling590 kWh/yr | 5.5 | $189 | |
| Daikin RXM35AVMA / FTXM35AVMA3.7 kW heating3.5 kW cooling595 kWh/yr | 5 | $190 | |
| Midea MFCA35VA-W/MFCA35VA-N3.6 kW heating3.5 kW cooling597 kWh/yr | 5.5 | $191 | |
| Actron Air WRC-035CS / WRE-035CS3.7 kW heating3.5 kW cooling610 kWh/yr | 5 | $195 | |
| Comfee CASG-XG35/CASN-XG353.8 kW heating3.5 kW cooling610 kWh/yr | 5 | $195 |
Air conditioners similar to the Hitachi RAC-P35YHAB
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Smart Lifestyle Australia SLA-35-CHSD3.8 kW heating3.5 kW cooling615 kWh/yr | 5 | $197 | |
| Actron Air WRC-035CS / WRE-035CS3.7 kW heating3.5 kW cooling610 kWh/yr | 5 | $195 | |
| Midea MFEP35VA-W/MFEP35VA-N3.6 kW heating3.5 kW cooling590 kWh/yr | 5.5 | $189 | |
| Midea MFEP35VB-W/MFEP35VB-N3.9 kW heating3.5 kW cooling619 kWh/yr | 6 | $198 | |
| Comfee CASG-XG35/CASN-XG353.8 kW heating3.5 kW cooling610 kWh/yr | 5 | $195 | |
| Actron Air WRC-035DS / WRE-035DS3.9 kW heating3.5 kW cooling619 kWh/yr | 6 | $198 | |
| Rinnai HSNRP35B3.8 kW heating3.5 kW cooling615 kWh/yr | 5 | $197 | |
| Daikin RXM35AVMA / FTXM35AVMA3.7 kW heating3.5 kW cooling595 kWh/yr | 5 | $190 |
Compare RAC-P35YHAB/RAS-P35YHAB with another model
Hitachi RAC-P35YHAB specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 3.50 kW
- Cooling power input
- 0.75 kW
- Rated heating capacity (7 Β°C)
- 4.30 kW
- Heating power input
- 0.88 kW
- EER, full load (tested)
- 4.53
- COP, full load (tested)
- 4.75
- Rated AEER
- 4.63
- Rated ACOP
- 4.86
- Standby power (PIA)
- 1.6 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 57 dB(A)
- Outdoor sound power
- 61 dB(A)
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- China, India
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Hitachi RAC-P35YHAB zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 197 | 385 |
| Coldresidential | residential | 5.5 | 3.0 | 134 | 1,204 |
| Mixedcommercial | commercial | β | β | 292 | 200 |
| Mixedresidential | residential | 5.0 | 3.5 | 212 | 448 |
| Hotcommercial | commercial | β | β | 755 | 42 |
| Hotresidential | residential | 5.5 | 4.0 | 619 | 66 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 220 W
- h__h2_ext_cap_power_rated
- 1270 W
- c__t1_half_cap_power_rated
- 300 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 340 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 4300 W
- h__h1_half_cap_heat_cap_rated
- 2150 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 150 W
- c__t1_min_cap_cooling_cap_rated
- 1000 W
- c__low_temp_full_cap_power_rated
- 685.5 W
- c__low_temp_half_cap_power_rated
- 230 W
- c__t1_half_cap_cooling_cap_rated
- 1750 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 1300 W
- c__low_temp_full_cap_cooling_cap_rated
- 3769.5 W
- c__low_temp_half_cap_cooling_cap_rated
- 1900 W
Australian GEMS registration details
- Registration number
- AAC6361
- GEMS registration id
- 142980
- Status
- approved, available (self-reported)
- Registration expires
- 25 November 2026
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 8
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: temperzone.com. How the derived figures are calculated.