Australia Β· costs in AUD

Reverse cycle split system air conditioner, floor mounted
Hitachi RAC-XJ35FHAE/RAF-XJ35RHAE Air Conditioner
Hitachi RAC-XJ35FHAE/RAF-XJ35RHAE is a 3.5 kW reverse cycle split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC10275).
- Energy rating (cooling)
- 4.5
- Heating: 2.5
- Annual electricity use
- 790 kWh
- 239 cooling + 551 heating
- Estimated running cost
- $253 / year
- $21 / month Β· $2,528 over 10 years
- Capacity
- 3.5 kW cooling
- 4.5 kW heating
12% more electricity than the median of 196 comparable 3.5 kW reverse cycle split system registrations (709 kWh a year) in the mixed zone. Uses less than 25% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 83% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Hitachi RAC-XJ35FHAE running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 1,644 | $526 | $5,261 |
| Mixed zone | 790 | $253 | $2,528 |
| Hot zone | 770 | $246 | $2,464 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 3.5 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Midea MFEP35VA-W/MFEP35VA-N3.6 kW heating3.5 kW cooling590 kWh/yr | 5.5 | $189 | |
| Daikin RXM35AVMA / FTXM35AVMA3.7 kW heating3.5 kW cooling595 kWh/yr | 5 | $190 | |
| Midea MFCA35VA-W/MFCA35VA-N3.6 kW heating3.5 kW cooling597 kWh/yr | 5.5 | $191 | |
| Comfee CASG-XG35/CASN-XG353.8 kW heating3.5 kW cooling610 kWh/yr | 5 | $195 | |
| Actron Air WRC-035CS / WRE-035CS3.7 kW heating3.5 kW cooling610 kWh/yr | 5 | $195 |
Air conditioners similar to the Hitachi RAC-XJ35FHAE
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Fujitsu AOTG12KVCA/AGTG12KVCA4.5 kW heating3.5 kW cooling817 kWh/yr | 4 | $261 | |
| Actron Air WRC-035DS / WRE-035DS3.9 kW heating3.5 kW cooling619 kWh/yr | 6 | $198 | |
| Daikin RXM35AVMA / FTXM35AVMA3.7 kW heating3.5 kW cooling595 kWh/yr | 5 | $190 | |
| Smart Lifestyle Australia SLA-35-CHSD3.8 kW heating3.5 kW cooling615 kWh/yr | 5 | $197 | |
| Midea MFEP35VA-W/MFEP35VA-N3.6 kW heating3.5 kW cooling590 kWh/yr | 5.5 | $189 | |
| Actron Air WRC-035CS / WRE-035CS3.7 kW heating3.5 kW cooling610 kWh/yr | 5 | $195 | |
| Comfee CASG-XG35/CASN-XG353.8 kW heating3.5 kW cooling610 kWh/yr | 5 | $195 | |
| Rinnai HSNRP35B3.8 kW heating3.5 kW cooling615 kWh/yr | 5 | $197 |
Compare RAC-XJ35FHAE/RAF-XJ35RHAE with another model
Hitachi RAC-XJ35FHAE specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Floor mounted
- Rated cooling capacity (35 Β°C)
- 3.50 kW
- Cooling power input
- 0.94 kW
- Rated heating capacity (7 Β°C)
- 4.50 kW
- Heating power input
- 1.05 kW
- EER, full load (tested)
- 4.26
- COP, full load (tested)
- 4.25
- Rated AEER
- 3.97
- Rated ACOP
- 3.88
- Standby power (PIA)
- 2.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 53 dB(A)
- Outdoor sound power
- 61 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Dimensions (WΓHΓD)
- 760 Γ 600 Γ 235 mm
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Hitachi RAC-XJ35FHAE zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 248 | 470 |
| Coldresidential | residential | 4.5 | 2.0 | 149 | 1,495 |
| Mixedcommercial | commercial | β | β | 350 | 242 |
| Mixedresidential | residential | 4.5 | 2.5 | 239 | 551 |
| Hotcommercial | commercial | β | β | 851 | 50 |
| Hotresidential | residential | 5.0 | 3.5 | 691 | 79 |
Part-load test points (21 values)
- c__t1_min_cap_power_rated
- 220 W
- h__h2_ext_cap_power_rated
- 1400 W
- c__t1_half_cap_power_rated
- 320 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 405 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 4200 W
- h__h1_half_cap_heat_cap_rated
- 2250 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 170 W
- c__t1_min_cap_cooling_cap_rated
- 1100 W
- c__low_temp_half_cap_power_rated
- 240 W
- c__t1_half_cap_cooling_cap_rated
- 1750 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 1400 W
- c__low_temp_half_cap_cooling_cap_rated
- 1900 W
Australian GEMS registration details
- Registration number
- AAC10275
- GEMS registration id
- 149817
- Status
- approved, available (self-reported)
- Registration expires
- 2 July 2031
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 8
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: temperzone.com. How the derived figures are calculated.