c/kWh
Energy rating (cooling)
2.5
Heating: 2.5
Annual electricity use
11,174 kWh
4,270 cooling + 6,904 heating
Estimated running cost
$3,576 / year
$298 / month Β· $35,757 over 10 years
Capacity
45 kW cooling
50 kW heating

19% less electricity than the median of 42 comparable 50 kW reverse cycle multi-split / vrf registrations (13,803 kWh a year) in the mixed zone. Uses less than 74% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 7% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Hitachi RAS-160RNCCLW running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 22,015$7,045$70,448
Mixed zone 11,174$3,576$35,757
Hot zone 12,758$4,083$40,826

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 45 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Toshiba MMY-MUP14S1HT8P-A40 kW heating40 kW cooling3,918 kWh/yr2.5$1,254
Panasonic U-16MF3R750 kW heating45 kW cooling4,064 kWh/yr2.5$1,300
Toshiba MMY-MUP16S1HT8P-A50 kW heating45 kW cooling4,443 kWh/yr2.5$1,422
Mitsubishi Electric PUHY-M350YXM-A40 kW heating40 kW cooling5,003 kWh/yr1.5$1,601
Mitsubishi Electric PUHY-M350YXM-A-BS40 kW heating40 kW cooling5,003 kWh/yr1.5$1,601

Air conditioners similar to the Hitachi RAS-160RNCCLW

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Mitsubishi Heavy Industries FDC450KXZE250 kW heating45 kW cooling11,292 kWh/yr2.5$3,613
Daikin REYA16AYM50 kW heating45 kW cooling11,471 kWh/yr3$3,671
Mitsubishi Electric PUHY-M400YXM-A45 kW heating45 kW cooling5,655 kWh/yr1.5$1,810
Toshiba MMY-MUP16S1HT8P-A50 kW heating45 kW cooling4,443 kWh/yr2.5$1,422
Mitsubishi Heavy Industries FDC450KXZRE245 kW heating45 kW cooling11,109 kWh/yr2$3,555
Daikin REYQ16TAY150 kW heating45 kW cooling14,331 kWh/yr2$4,586
Panasonic U-16MF3R750 kW heating45 kW cooling4,064 kWh/yr2.5$1,300
Mitsubishi Electric PUHY-M400YXM-A-BS45 kW heating45 kW cooling5,655 kWh/yr1.5$1,810

Compare RAS-160RNCCLW with another model

Hitachi RAS-160RNCCLW specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Ducted or non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
45.00 kW
Cooling power input
12.18 kW
Rated heating capacity (7 Β°C)
50.00 kW
Heating power input
13.33 kW
EER, full load (tested)
3.54
COP, full load (tested)
3.89
Rated AEER
3.55
Rated ACOP
3.61
Standby power (PIA)
149.0 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Hitachi RAS-160RNCCLW zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––5,5616,166
Coldresidential2.51.52,79419,221
Mixedcommercial––6,9563,070
Mixedresidential2.52.54,2706,904
Hotcommercial––15,171824
Hotresidential3.03.511,5511,207
Part-load test points (16 values)
h__h2_ext_cap_power_rated
14060 W
c__t1_half_cap_power_rated
4080 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
4550 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
38040 W
h__h1_half_cap_heat_cap_rated
25000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
22500 W
c__low_temp_have_half_cap_results
No

Australian GEMS registration details

Registration number
AAC7330
GEMS registration id
151038
Status
approved, available (self-reported)
Registration expires
1 March 2028
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 21

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: temperzone.com. How the derived figures are calculated.