c/kWh
Energy rating (cooling)
2.5
Heating: 2
Annual electricity use
15,079 kWh
5,257 cooling + 9,822 heating
Estimated running cost
$4,825 / year
$402 / month Β· $48,253 over 10 years
Capacity
56 kW cooling
63 kW heating

9% more electricity than the median of 42 comparable 50 kW reverse cycle multi-split / vrf registrations (13,803 kWh a year) in the mixed zone. Uses less than 36% of them.

Across all 3,681 air conditioner registrations sold in Australia, it uses less than 4% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Hitachi RAS-200RNCCLW running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 31,030$9,930$99,296
Mixed zone 15,079$4,825$48,253
Hot zone 15,436$4,940$49,395

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 56 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Toshiba MMY-MUP20S1HT8P-A63 kW heating56 kW cooling5,421 kWh/yr2.5$1,735
Toshiba MMY-MUP2201FT8P-A61.5 kW heating61.5 kW cooling5,429 kWh/yr3$1,737
Mitsubishi Electric PUHY-M450YXM-A50 kW heating50 kW cooling6,542 kWh/yr1.5$2,093
Mitsubishi Electric PUHY-M450YXM series50 kW heating50 kW cooling6,542 kWh/yr1.5$2,093
Hitachi RAS-180RNCCLW56 kW heating50.4 kW cooling11,937 kWh/yr2.5$3,820

Air conditioners similar to the Hitachi RAS-200RNCCLW

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Mitsubishi Heavy Industries FDC560KXZE263 kW heating56 kW cooling16,171 kWh/yr2.5$5,175
Mitsubishi Electric PUHY-M500YXM series56 kW heating56 kW cooling8,090 kWh/yr1$2,589
Mitsubishi Electric PUHY-M500YXM-A56 kW heating56 kW cooling8,090 kWh/yr1$2,589
Daikin REYA20AYM63 kW heating56 kW cooling13,423 kWh/yr3$4,295
Toshiba MMY-MUP20S1HT8P-A63 kW heating56 kW cooling5,421 kWh/yr2.5$1,735
Toshiba MMY-MUP2001FT8P-A56 kW heating56 kW cooling16,337 kWh/yr3$5,228
Daikin REYQ20TAY163 kW heating56 kW cooling19,870 kWh/yr2$6,358

Other Hitachi models of similar capacity

ModelStarsEst. cost / yrCompare
Hitachi RAS-200RNCBLW63 kW heating56 kW cooling13,993 kWh/yr2$4,478

Compare RAS-200RNCCLW with another model

Hitachi RAS-200RNCCLW specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Ducted or non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
56.00 kW
Cooling power input
13.44 kW
Rated heating capacity (7 Β°C)
63.00 kW
Heating power input
14.36 kW
EER, full load (tested)
3.93
COP, full load (tested)
4.55
Rated AEER
3.93
Rated ACOP
4.15
Standby power (PIA)
240.0 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Hitachi RAS-200RNCCLW zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––6,8578,579
Coldresidential2.01.53,51927,511
Mixedcommercial––8,4724,209
Mixedresidential2.52.05,2579,822
Hotcommercial––18,0651,158
Hotresidential3.53.013,7671,669
Part-load test points (16 values)
h__h2_ext_cap_power_rated
15230 W
c__t1_half_cap_power_rated
4970 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
5870 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
41980 W
h__h1_half_cap_heat_cap_rated
31500 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
28000 W
c__low_temp_have_half_cap_results
No

Australian GEMS registration details

Registration number
AAC7326
GEMS registration id
151041
Status
approved, available (self-reported)
Registration expires
1 March 2028
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 21

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: temperzone.com. How the derived figures are calculated.