c/kWh
Energy rating (cooling)
4.5
Heating: 3
Annual electricity use
673 kWh
233 cooling + 440 heating
Estimated running cost
$215 / year
$18 / month Β· $2,154 over 10 years
Capacity
3.5 kW cooling
3.6 kW heating

5% less electricity than the median of 196 comparable 3.5 kW reverse cycle split system registrations (709 kWh a year) in the mixed zone. Uses less than 75% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 87% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Hyundai HYSSSAC35TC running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,287$412$4,118
Mixed zone 673$215$2,154
Hot zone 697$223$2,230

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 3.5 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Midea MFEP35VA-W/MFEP35VA-N3.6 kW heating3.5 kW cooling590 kWh/yr5.5$189
Daikin RXM35AVMA / FTXM35AVMA3.7 kW heating3.5 kW cooling595 kWh/yr5$190
Midea MFCA35VA-W/MFCA35VA-N3.6 kW heating3.5 kW cooling597 kWh/yr5.5$191
Comfee CASG-XG35/CASN-XG353.8 kW heating3.5 kW cooling610 kWh/yr5$195
Actron Air WRC-035CS / WRE-035CS3.7 kW heating3.5 kW cooling610 kWh/yr5$195

Air conditioners similar to the Hyundai HYSSSAC35TC

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Kogan KASSSAC35T*3.6 kW heating3.5 kW cooling679 kWh/yr4.5$217
Kogan KASSSAC35TD3.6 kW heating3.5 kW cooling679 kWh/yr4.5$217
Braemar TCHV03T1S/TSHV03T1S3.6 kW heating3.5 kW cooling693 kWh/yr4$222
Maxa LZL35 ODU / LZL35 IDU3.6 kW heating3.5 kW cooling673 kWh/yr4.5$215
Domain ISR-35Q-OUT/ISR-35Q-IND3.6 kW heating3.5 kW cooling672 kWh/yr4.5$215
Bonaire STH035S1AE/STH035S1AI3.6 kW heating3.5 kW cooling693 kWh/yr4$222
TCL TAC-13CHSD/XA72IG3.6 kW heating3.5 kW cooling679 kWh/yr4.5$217
TCL TAC-13CHSD/VEIH3.6 kW heating3.5 kW cooling673 kWh/yr4.5$215

Compare HYSSSAC35TC with another model

Hyundai HYSSSAC35TC specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
3.53 kW
Cooling power input
0.87 kW
Rated heating capacity (7 Β°C)
3.65 kW
Heating power input
0.85 kW
EER, full load (tested)
4.02
COP, full load (tested)
4.23
Rated AEER
4.00
Rated ACOP
4.24
Standby power (PIA)
3.4 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
53.9 dB(A)
Outdoor sound power
63.8 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Hyundai HYSSSAC35TC zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––17370
Coldresidential4.52.51471,140
Mixedcommercial––192198
Mixedresidential4.53.0233440
Hotcommercial––52645
Hotresidential5.53.562869
Part-load test points (18 values)
h__h2_ext_cap_power_rated
1175 W
c__t1_half_cap_power_rated
480 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
323 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
3800 W
h__h1_half_cap_heat_cap_rated
1770 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
245 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
1870 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
1810 W

Other model numbers on registration AAC8913

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC8913
GEMS registration id
169734
Status
approved, available (self-reported)
Registration expires
26 May 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
HYSSSAC35T*
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.