c/kWh
Energy rating (cooling)
3.5
Heating: 3
Annual electricity use
2,217 kWh
827 cooling + 1,390 heating
Estimated running cost
$709 / year
$59 / month Β· $7,094 over 10 years
Capacity
10.6 kW cooling
11.4 kW heating

13% less electricity than the median of 17 comparable 10 kW reverse cycle multi-split / vrf registrations (2,557 kWh a year) in the mixed zone. Uses less than 94% of them.

Across all 3,681 air conditioner registrations sold in Australia, it uses less than 47% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Kinghome KWHD(36)NK6PO running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,364$1,396$13,965
Mixed zone 2,217$709$7,094
Hot zone 2,596$831$8,307

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners similar to the Kinghome KWHD(36)NK6PO

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Carrier 38VS00418SHCSS12.5 kW heating11.2 kW cooling2,672 kWh/yr2.5$855
Toshiba MCY-MHP0405HT12.5 kW heating11.2 kW cooling2,672 kWh/yr2.5$855
Midea MV8M-100WV2N812 kW heating10 kW cooling2,776 kWh/yr2$888
LG 5MXM100MA010.3 kW heating10 kW cooling2,234 kWh/yr3$715
Actron Air MMV-100CS12 kW heating10 kW cooling2,776 kWh/yr2$888
Daikin RSUYQ4AVMA12.5 kW heating11.2 kW cooling2,555 kWh/yr2.5$818
Daikin RSUYQ4A2VMA12.5 kW heating11.2 kW cooling2,557 kWh/yr2.5$818
Hisense AVW-34HJFAH111.2 kW heating10 kW cooling2,461 kWh/yr3$788

Compare KWHD(36)NK6PO with another model

Kinghome KWHD(36)NK6PO specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Non-ducted
Indoor unit
Floor mounted
Rated cooling capacity (35 Β°C)
10.60 kW
Cooling power input
2.65 kW
Rated heating capacity (7 Β°C)
11.40 kW
Heating power input
2.85 kW
EER, full load (tested)
4.12
COP, full load (tested)
4.18
Rated AEER
3.95
Rated ACOP
3.95
Standby power (PIA)
10.5 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
64.6 dB(A)
Outdoor sound power
69.1 dB(A)
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Kinghome KWHD(36)NK6PO zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,1131,201
Coldresidential3.52.05243,840
Mixedcommercial––1,412613
Mixedresidential3.53.08271,390
Hotcommercial––3,168136
Hotresidential4.03.52,386210
Part-load test points (16 values)
h__h2_ext_cap_power_rated
3900 W
c__t1_half_cap_power_rated
860 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1000 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
10500 W
h__h1_half_cap_heat_cap_rated
5700 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
5300 W
c__low_temp_have_half_cap_results
No

Australian GEMS registration details

Registration number
AAC10355
GEMS registration id
181250
Status
approved, available (self-reported)
Registration expires
3 August 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 20

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.