c/kWh
Energy rating (cooling)
1.5
Annual electricity use
2,201 kWh
Estimated running cost
$704 / year
$59 / month Β· $7,043 over 10 years
Capacity
17 kW cooling

About the same electricity as the median of 5 comparable 18 kW cooling only ducted split system registrations (2,201 kWh a year) in the mixed zone. Uses less than 40% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 47% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Lennox TSA060S41-3 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,467$469$4,694
Mixed zone 2,201$704$7,043
Hot zone 6,365$2,037$20,368

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 17 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Brivis DONSC17Z71 / DINXU17Z716.2 kW cooling1,430 kWh/yr3$458
Bonaire CRC6940017/CRC694011717 kW cooling1,431 kWh/yr3$458
Bonaire CRC6943017/CRC694011717 kW cooling1,455 kWh/yr3$466
Actron Air CCA170T / EAA170S16.7 kW cooling1,894 kWh/yr2$606
Braemar KCHV160D1B/KACV160D1S16 kW cooling1,956 kWh/yr1.5$626

Air conditioners similar to the Lennox TSA060S41-3

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Bonaire CRC6943017/CRC694011717 kW cooling1,455 kWh/yr3$466
Bonaire CRC6940017/CRC694011717 kW cooling1,431 kWh/yr3$458
Diamond SD01717 kW cooling2,262 kWh/yr1.5$724
Actron Air CCA170T / EAA170S16.7 kW cooling1,894 kWh/yr2$606
Actron Air CCA170S / EAA170S16.5 kW cooling1,969 kWh/yr2$630
Brivis DONSC17Z71 / DINXU17Z716.2 kW cooling1,430 kWh/yr3$458
Braemar KCHV160D1B/KACV160D1S16 kW cooling1,956 kWh/yr1.5$626

Compare TSA060S41-3/CH33-62D-2F-3 with another model

Lennox TSA060S41-3 specifications

Type
Cooling only
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
17.04 kW
Cooling power input
5.07 kW
Rated heating capacity (7 Β°C)
–
Heating power input
–
EER, full load (tested)
3.26
COP, full load (tested)
–
Rated AEER
3.30
Rated ACOP
–
Standby power (PIA)
26.9 W
Compressor
Fixed speed
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
80 dB(A)
Demand response (AS/NZS 4755)
No
Country of manufacture
United States of America

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Lennox TSA060S41-3 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––3,308–
Coldresidential1.5–1,467–
Mixedcommercial––4,067–
Mixedresidential1.5–2,201–
Hotcommercial––8,725–
Hotresidential1.5–6,365–
Part-load test points (1 values)
c__low_temp_have_full_cap_results
No

Other model numbers on registration AAC6337

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC6337
GEMS registration id
142623
Status
approved, available (self-reported)
Registration expires
10 November 2026
Registered for sale in
Australia, New Zealand
Family
TSA060S41-3
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: lennox.com. How the derived figures are calculated.