Australia Β· costs in AUD

Reverse cycle split system air conditioner
Mdv C-UV-170N8-QC3W / CDV-170HFN8-QC3W Air Conditioner
Mdv C-UV-170N8-QC3W / CDV-170HFN8-QC3W is a 17 kW reverse cycle ducted split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC7216).
- Energy rating (cooling)
- 3.5
- Heating: 2.5
- Annual electricity use
- 3,707 kWh
- 1,333 cooling + 2,374 heating
- Estimated running cost
- $1,186 / year
- $99 / month Β· $11,862 over 10 years
- Capacity
- 17 kW cooling
- 17.5 kW heating
15% less electricity than the median of 53 comparable 18 kW reverse cycle ducted split system registrations (4,376 kWh a year) in the mixed zone. Uses less than 74% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 26% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Mdv running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 7,389 | $2,364 | $23,645 |
| Mixed zone | 3,707 | $1,186 | $11,862 |
| Hot zone | 3,898 | $1,247 | $12,474 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 17 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| AirSmart IES-700-AC15.8 kW heating17 kW cooling3,358 kWh/yr | 3.5 | $1,075 | |
| AirSmart IES-70015.8 kW heating17 kW cooling3,358 kWh/yr | 3.5 | $1,075 | |
| Actron Air LRC-170CS / LRE-170CS17.6 kW heating16.6 kW cooling3,556 kWh/yr | 3.5 | $1,138 | |
| Midea DUCMI170IHB/UCMI170OB17.5 kW heating17 kW cooling3,585 kWh/yr | 3.5 | $1,147 |
Air conditioners similar to the Mdv
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Rinnai DONSR17Z72/DINLR17Z7217.5 kW heating17 kW cooling3,627 kWh/yr | 4 | $1,161 | |
| Rinnai DONSGHW18Z2/DINLR17Z7217.5 kW heating17 kW cooling3,627 kWh/yr | 4 | $1,161 | |
| AirSmart IES-***15.8 kW heating17 kW cooling3,358 kWh/yr | 3.5 | $1,075 | |
| Carrier 38QSH170D8S / 42QSH170D8S17 kW heating17 kW cooling3,597 kWh/yr | 3 | $1,151 | |
| Midea UCMI170OB/DUCMI170IHB17.5 kW heating17 kW cooling3,655 kWh/yr | 3 | $1,170 | |
| AirSmart IES-70015.8 kW heating17 kW cooling3,358 kWh/yr | 3.5 | $1,075 | |
| Midea DUCMI170IHB/UCMI170OB17.5 kW heating17 kW cooling3,585 kWh/yr | 3.5 | $1,147 | |
| Kaden KDI60 / KDI6018 kW heating17 kW cooling3,663 kWh/yr | 3.5 | $1,172 |
Compare C-UV-170N8-QC3W / CDV-170HFN8-QC3W with another model
Mdv specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 17.00 kW
- Cooling power input
- 5.25 kW
- Rated heating capacity (7 Β°C)
- 17.50 kW
- Heating power input
- 4.50 kW
- EER, full load (tested)
- 3.30
- COP, full load (tested)
- 3.92
- Rated AEER
- 3.21
- Rated ACOP
- 3.85
- Standby power (PIA)
- 13.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- 70.9 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Mdv zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,807 | 1,985 |
| Coldresidential | residential | 4.0 | 1.5 | 822 | 6,567 |
| Mixedcommercial | commercial | β | β | 1,027 | 996 |
| Mixedresidential | residential | 3.5 | 2.5 | 1,333 | 2,374 |
| Hotcommercial | commercial | β | β | 4,090 | 212 |
| Hotresidential | residential | 4.5 | 3.0 | 3,560 | 338 |
Part-load test points (25 values)
- c__t1_min_cap_power_rated
- 1150 W
- h__h1_min_cap_power_rated
- 780 W
- h__h2_ext_cap_power_rated
- 4870 W
- c__t1_half_cap_power_rated
- 2750 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 1750 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 4100 W
- h__h2_ext_cap_heat_cap_rated
- 14100 W
- h__h1_half_cap_heat_cap_rated
- 8000 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 670 W
- c__t1_min_cap_cooling_cap_rated
- 4650 W
- c__low_temp_full_cap_power_rated
- 4798.5 W
- c__low_temp_half_cap_power_rated
- 1340 W
- c__t1_half_cap_cooling_cap_rated
- 7950 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 4110 W
- c__low_temp_full_cap_cooling_cap_rated
- 18309 W
- c__low_temp_half_cap_cooling_cap_rated
- 8250 W
Australian GEMS registration details
- Registration number
- AAC7216
- GEMS registration id
- 151695
- Status
- approved, available (self-reported)
- Registration expires
- 20 December 2027
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 11