Reverse cycle split system air conditioner, wall hung
Midea MFAB-50WC/MFAB-50NC Air Conditioner
Midea MFAB-50WC/MFAB-50NC is a 5 kW reverse cycle split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC6303).
- Energy rating (cooling)
- 4
- Heating: 2.5
- Annual electricity use
- 1,045 kWh
- 360 cooling + 685 heating
- Estimated running cost
- $334 / year
- $28 / month Β· $3,344 over 10 years
- Capacity
- 5 kW cooling
- 5.2 kW heating
4% less electricity than the median of 240 comparable 5 kW reverse cycle split system registrations (1,093 kWh a year) in the mixed zone. Uses less than 73% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 77% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Midea MFAB-50WC running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 2,103 | $673 | $6,730 |
| Mixed zone | 1,045 | $334 | $3,344 |
| Hot zone | 1,159 | $371 | $3,709 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 5 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling839 kWh/yr | 4 | $268 | |
| Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling847 kWh/yr | 4 | $271 | |
| Actron Air WRC-050CS / WRE-050CS5 kW heating5 kW cooling942 kWh/yr | 4.5 | $301 | |
| Panasonic CU-HZ50DKR / CS-HZ50DKR6 kW heating5 kW cooling949 kWh/yr | 5 | $304 | |
| Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling949 kWh/yr | 4 | $304 |
Air conditioners similar to the Midea MFAB-50WC
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Rinnai HONRPX50/HINRPX50M6 kW heating5 kW cooling997 kWh/yr | 5 | $319 | |
| Haier 1U50PFHRA / AS50PFHRA5.3 kW heating5 kW cooling990 kWh/yr | 4 | $317 | |
| Daikin RXM50WVMA / FTXM50WVMA6 kW heating5 kW cooling942 kWh/yr | 5 | $301 | |
| Hisense HAWG18KR5.3 kW heating5 kW cooling1,012 kWh/yr | 4 | $324 | |
| Panasonic CU-Z50DKR-1 / CS-Z50DKRW-16 kW heating5 kW cooling1,008 kWh/yr | 4.5 | $323 | |
| Actron Air WRC-050CS / WRE-050CS5 kW heating5 kW cooling942 kWh/yr | 4.5 | $301 | |
| Daikin RXM50AVMA / FTXM50AVMA6 kW heating5 kW cooling937 kWh/yr | 5 | $300 | |
| Panasonic CU-HZ50DKR / CS-HZ50DKR6 kW heating5 kW cooling949 kWh/yr | 5 | $304 |
Compare MFAB-50WC/MFAB-50NC with another model
Midea MFAB-50WC specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 5.00 kW
- Cooling power input
- 1.30 kW
- Rated heating capacity (7 Β°C)
- 5.20 kW
- Heating power input
- 1.35 kW
- EER, full load (tested)
- 3.92
- COP, full load (tested)
- 3.95
- Rated AEER
- 3.84
- Rated ACOP
- 3.84
- Standby power (PIA)
- 1.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 57 dB(A)
- Outdoor sound power
- 65 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Midea MFAB-50WC zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 317 | 589 |
| Coldresidential | residential | 4.5 | 2.0 | 226 | 1,877 |
| Mixedcommercial | commercial | β | β | 495 | 301 |
| Mixedresidential | residential | 4.0 | 2.5 | 360 | 685 |
| Hotcommercial | commercial | β | β | 1,285 | 60 |
| Hotresidential | residential | 4.5 | 3.0 | 1,063 | 96 |
Part-load test points (25 values)
- c__t1_min_cap_power_rated
- 495 W
- h__h1_min_cap_power_rated
- 460 W
- h__h2_ext_cap_power_rated
- 1755 W
- c__t1_half_cap_power_rated
- 535 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 530 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 2310 W
- h__h2_ext_cap_heat_cap_rated
- 4700 W
- h__h1_half_cap_heat_cap_rated
- 2600 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 320 W
- c__t1_min_cap_cooling_cap_rated
- 2350 W
- c__low_temp_full_cap_power_rated
- 1188.2 W
- c__low_temp_half_cap_power_rated
- 395 W
- c__t1_half_cap_cooling_cap_rated
- 2600 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 2340 W
- c__low_temp_full_cap_cooling_cap_rated
- 5385 W
- c__low_temp_half_cap_cooling_cap_rated
- 2730 W
Australian GEMS registration details
- Registration number
- AAC6303
- GEMS registration id
- 142157
- Status
- approved, available (self-reported)
- Registration expires
- 24 October 2026
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9