Australia Β· costs in AUD

Reverse cycle split system air conditioner, wall hung
Midea MFEF60VA-W/MFEF60VA-N Air Conditioner
Midea MFEF60VA-W/MFEF60VA-N is a 6.1 kW reverse cycle split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC8958).
- Energy rating (cooling)
- 3.5
- Heating: 2.5
- Annual electricity use
- 1,340 kWh
- 485 cooling + 855 heating
- Estimated running cost
- $429 / year
- $36 / month Β· $4,288 over 10 years
- Capacity
- 6.1 kW cooling
- 6.5 kW heating
About the same electricity as the median of 104 comparable 6 kW reverse cycle split system registrations (1,340 kWh a year) in the mixed zone. Uses less than 46% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 67% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Midea MFEF60VA-W running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 2,794 | $894 | $8,941 |
| Mixed zone | 1,340 | $429 | $4,288 |
| Hot zone | 1,546 | $495 | $4,947 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 6.1 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-60PZ4R5 / S-6071PU3E6 kW heating6 kW cooling1,092 kWh/yr | 3.5 | $349 | |
| Panasonic U-60PZ3R5 / S-6071PU3E6 kW heating6 kW cooling1,101 kWh/yr | 3.5 | $352 | |
| Rinnai HONRPX60/HINRPX60M6.5 kW heating6 kW cooling1,177 kWh/yr | 4.5 | $377 | |
| Midea MFEZ60VA-W/MFEZ60VA-N6.5 kW heating6 kW cooling1,177 kWh/yr | 4.5 | $377 | |
| Actron Air WRC-060DS / WRE-060DS6.6 kW heating6 kW cooling1,203 kWh/yr | 4.5 | $385 |
Air conditioners similar to the Midea MFEF60VA-W
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Carrier Carrier Ambi6.5 kW heating6.1 kW cooling1,340 kWh/yr | 3.5 | $429 | |
| Mitsubishi Electric MUZ-LN60VG2/MSZ-LN60VGDV6.8 kW heating6.1 kW cooling1,418 kWh/yr | 3 | $454 | |
| Mitsubishi Electric MUZ-LN60VGHZ/MSZ-LN60VGDV6.8 kW heating6.1 kW cooling1,418 kWh/yr | 3 | $454 | |
| Mitsubishi Heavy Industries SRC60ZSXA-W / SRK60ZSXA-W6.8 kW heating6.1 kW cooling1,334 kWh/yr | 3 | $427 | |
| Comfee CASG-XG60/CASN-XG606.4 kW heating6.1 kW cooling1,264 kWh/yr | 4 | $404 | |
| LG WH21SLU-23 / WH21SLN-237 kW heating6.1 kW cooling1,316 kWh/yr | 4.5 | $421 | |
| Mitsubishi Heavy Industries SRC60ZSXA-W/SRK60ZSXA-WF6.8 kW heating6.1 kW cooling1,337 kWh/yr | 3 | $428 | |
| Rinnai HONRPX60/HINRPX60M6.5 kW heating6 kW cooling1,177 kWh/yr | 4.5 | $377 |
Compare MFEF60VA-W/MFEF60VA-N with another model
Midea MFEF60VA-W specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 6.10 kW
- Cooling power input
- 1.78 kW
- Rated heating capacity (7 Β°C)
- 6.55 kW
- Heating power input
- 1.69 kW
- EER, full load (tested)
- 3.40
- COP, full load (tested)
- 3.85
- Rated AEER
- 3.42
- Rated ACOP
- 3.87
- Standby power (PIA)
- 0.6 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 62.7 dB(A)
- Outdoor sound power
- 67.4 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Midea MFEF60VA-W zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 483 | 765 |
| Coldresidential | residential | 4.0 | 1.5 | 303 | 2,491 |
| Mixedcommercial | commercial | β | β | 702 | 375 |
| Mixedresidential | residential | 3.5 | 2.5 | 485 | 855 |
| Hotcommercial | commercial | β | β | 1,751 | 68 |
| Hotresidential | residential | 4.0 | 3.5 | 1,437 | 109 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 480 W
- h__h1_min_cap_power_rated
- 445 W
- h__h2_ext_cap_power_rated
- 1630 W
- c__t1_half_cap_power_rated
- 710 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 618 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 2400 W
- h__h2_ext_cap_heat_cap_rated
- 4700 W
- h__h1_half_cap_heat_cap_rated
- 3280 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 355 W
- c__t1_min_cap_cooling_cap_rated
- 1900 W
- c__low_temp_half_cap_power_rated
- 510 W
- c__t1_half_cap_cooling_cap_rated
- 3050 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 2430 W
- c__low_temp_half_cap_cooling_cap_rated
- 3200 W
Australian GEMS registration details
- Registration number
- AAC8958
- GEMS registration id
- 169574
- Status
- approved, available (self-reported)
- Registration expires
- 3 June 2030
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.