Australia Β· costs in AUD

Reverse cycle split system air conditioner, cassette
Midea UCMI105OB/CASMI105IB Air Conditioner
Midea UCMI105OB/CASMI105IB is a 10.5 kW reverse cycle split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC8069).
- Energy rating (cooling)
- 3.5
- Heating: 2.5
- Annual electricity use
- 2,317 kWh
- 833 cooling + 1,484 heating
- Estimated running cost
- $741 / year
- $62 / month Β· $7,414 over 10 years
- Capacity
- 10.5 kW cooling
- 11.5 kW heating
4% more electricity than the median of 122 comparable 10 kW reverse cycle split system registrations (2,236 kWh a year) in the mixed zone. Uses less than 43% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 46% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Midea UCMI105OB running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 4,587 | $1,468 | $14,678 |
| Mixed zone | 2,317 | $741 | $7,414 |
| Hot zone | 2,561 | $820 | $8,195 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 10.5 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,492 kWh/yr | 2.5 | $477 | |
| Panasonic U-100PZ4R5 / S-1014PU3E10 kW heating10 kW cooling1,846 kWh/yr | 3.5 | $591 | |
| Panasonic U-100PZ4R8 / S-1014PU3E10 kW heating10 kW cooling1,918 kWh/yr | 3.5 | $614 | |
| Daikin RZAV100F2Y1 / FCA100CVMA12 kW heating10 kW cooling1,975 kWh/yr | 4 | $632 | |
| Mitsubishi Heavy Industries DXC33ZRA-W / DXK33ZRA-WF110.3 kW heating9.5 kW cooling2,054 kWh/yr | 3.5 | $657 |
Air conditioners similar to the Midea UCMI105OB
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Kaden KCI36 / KCI3611 kW heating10.5 kW cooling2,119 kWh/yr | 4 | $678 | |
| Mdv C-UVC-105HFN8-QC3W/CSV-105N8-QC3W11 kW heating10.5 kW cooling2,119 kWh/yr | 4 | $678 | |
| Mdv C-UV-105N8-QC3W / CSV-105N8-QC3W11 kW heating10.5 kW cooling2,258 kWh/yr | 3.5 | $723 | |
| Hisense AUW-100U4RK1/ AUC-100UR4RKC111 kW heating10.2 kW cooling2,682 kWh/yr | 2.5 | $858 | |
| Braemar KCHV100D1B/KBHV100D1S12.1 kW heating10.2 kW cooling2,963 kWh/yr | 3 | $948 | |
| Braemar KCHV100D1B/KBHV100D1S12 kW heating10.1 kW cooling2,922 kWh/yr | 3 | $935 | |
| Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,492 kWh/yr | 2.5 | $477 | |
| Panasonic U-100PZ4R5 / S-1014PU3E10 kW heating10 kW cooling1,846 kWh/yr | 3.5 | $591 |
Compare UCMI105OB/CASMI105IB with another model
Midea UCMI105OB specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Cassette
- Rated cooling capacity (35 Β°C)
- 10.50 kW
- Cooling power input
- 2.86 kW
- Rated heating capacity (7 Β°C)
- 11.50 kW
- Heating power input
- 2.70 kW
- EER, full load (tested)
- 3.58
- COP, full load (tested)
- 4.08
- Rated AEER
- 3.63
- Rated ACOP
- 4.21
- Standby power (PIA)
- 10.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 64 dB(A)
- Outdoor sound power
- 70.4 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Midea UCMI105OB zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 690 | 1,282 |
| Coldresidential | residential | 3.5 | 2.0 | 531 | 4,056 |
| Mixedcommercial | commercial | β | β | 1,107 | 662 |
| Mixedresidential | residential | 3.5 | 2.5 | 833 | 1,484 |
| Hotcommercial | commercial | β | β | 2,590 | 146 |
| Hotresidential | residential | 4.0 | 3.0 | 2,335 | 226 |
Part-load test points (25 values)
- c__t1_min_cap_power_rated
- 631 W
- h__h1_min_cap_power_rated
- 491 W
- h__h2_ext_cap_power_rated
- 3357 W
- c__t1_half_cap_power_rated
- 1543 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 1121 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 2301 W
- h__h2_ext_cap_heat_cap_rated
- 9839 W
- h__h1_half_cap_heat_cap_rated
- 5559 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 440 W
- c__t1_min_cap_cooling_cap_rated
- 3077 W
- c__low_temp_full_cap_power_rated
- 2614.04 W
- c__low_temp_half_cap_power_rated
- 900 W
- c__t1_half_cap_cooling_cap_rated
- 5606 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 3220 W
- c__low_temp_full_cap_cooling_cap_rated
- 11308.5 W
- c__low_temp_half_cap_cooling_cap_rated
- 5590 W
Australian GEMS registration details
- Registration number
- AAC8069
- GEMS registration id
- 159593
- Status
- approved, available (self-reported)
- Registration expires
- 20 February 2029
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 11