c/kWh
Energy rating (cooling)
3.5
Annual electricity use
330 kWh
Estimated running cost
$106 / year
$9 / month Β· $1,056 over 10 years
Capacity
4.2 kW cooling

21% more electricity than the median of 23 comparable 3.5 kW cooling only split system registrations (273 kWh a year) in the mixed zone. Uses less than 4% of them.

Across all 3,638 air conditioner registrations sold in Australia, it uses less than 98% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Mitsubishi Electric MUY-GW42VFD2 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 207$66$662
Mixed zone 330$106$1,056
Hot zone 934$299$2,989

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners similar to the Mitsubishi Electric MUY-GW42VFD2

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Daikin RKM46WVMA / FTKM46WVMA4.6 kW cooling337 kWh/yr4$108
Daikin RKM46W2VMA / FTKM46W2VMA4.6 kW cooling341 kWh/yr4$109

Other Mitsubishi Electric models of similar capacity

ModelStarsEst. cost / yrCompare
Mitsubishi Electric MUY-GW42VFD/MSY-GW42VFD4.2 kW cooling365 kWh/yr3$117

Compare MUY-GW42VFD2/MSY-GW42VFD with another model

Mitsubishi Electric MUY-GW42VFD2 specifications

Type
Cooling only
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
4.20 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
–
Heating power input
–
EER, full load (tested)
3.57
COP, full load (tested)
–
Rated AEER
3.51
Rated ACOP
–
Standby power (PIA)
5.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
57 dB(A)
Outdoor sound power
59.5 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Mitsubishi Electric MUY-GW42VFD2 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––371–
Coldresidential3.5–207–
Mixedcommercial––504–
Mixedresidential3.5–330–
Hotcommercial––1,147–
Hotresidential4.0–934–
Part-load test points (9 values)
c__t1_half_cap_power_rated
420 W
c__t1_have_min_cap_results
No
c__low_temp_min_cap_power_rated
135 W
c__low_temp_half_cap_power_rated
295 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
2100 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
1160 W
c__low_temp_half_cap_cooling_cap_rated
2140 W

Other model numbers on registration AAC9098

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC9098
GEMS registration id
–
Status
approved
Registration expires
20 July 2030
Registered for sale in
Australia, New Zealand
Family
MUY-GW42VFD2/MSY-GW42VFD2 Series
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
9

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. Manufacturer: mitsubishielectric.com.au. How the derived figures are calculated.