Australia Β· costs in AUD
Reverse cycle split system air conditioner, wall hung
Mitsubishi Heavy Industries DXC07ZTLA-W/DXK07ZTLA-W Air Conditioner
Mitsubishi Heavy Industries DXC07ZTLA-W/DXK07ZTLA-W is a 2 kW reverse cycle split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC7085).
- Energy rating (cooling)
- 2.5
- Heating: 3
- Annual electricity use
- 520 kWh
- 187 cooling + 333 heating
- Estimated running cost
- $166 / year
- $14 / month Β· $1,664 over 10 years
- Capacity
- 2 kW cooling
- 2.7 kW heating
23% more electricity than the median of 62 comparable 2 kW reverse cycle split system registrations (422 kWh a year) in the mixed zone. Uses less than 19% of them.
Across all 3,681 air conditioner registrations sold in Australia, it uses less than 93% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Mitsubishi Heavy Industries DXC07ZTLA-W running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 977 | $313 | $3,126 |
| Mixed zone | 520 | $166 | $1,664 |
| Hot zone | 567 | $181 | $1,814 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 2 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| TCL TAC-06CHSD series1.8 kW heating1.8 kW cooling348 kWh/yr | 4 | $111 | |
| TCL TAC-06CHSD/TPG21IH1.8 kW heating1.8 kW cooling348 kWh/yr | 4 | $111 | |
| Maxa LZL17 ODU / LZL17 IDU1.8 kW heating1.8 kW cooling354 kWh/yr | 3.5 | $113 | |
| Comfee CASG-XG20/CASN-XG202.2 kW heating2 kW cooling367 kWh/yr | 5 | $117 | |
| Midea MFAB-20WC/MFAB-20NC2.3 kW heating2 kW cooling370 kWh/yr | 5 | $118 |
Air conditioners similar to the Mitsubishi Heavy Industries DXC07ZTLA-W
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Kaden KSI062.3 kW heating2 kW cooling370 kWh/yr | 5 | $118 | |
| Comfee CASG-XG20/CASN-XG202.2 kW heating2 kW cooling367 kWh/yr | 5 | $117 | |
| Daikin RXV20AVMA / FTXV20AVMA2.7 kW heating2 kW cooling396 kWh/yr | 5 | $127 | |
| Midea MFAB-20WC/MFAB-20NC2.3 kW heating2 kW cooling370 kWh/yr | 5 | $118 | |
| Carrier 38QHG020N8/42QHG020N8-12.2 kW heating2 kW cooling378 kWh/yr | 5 | $121 | |
| Midea MFXP20W/MFXP20N2.3 kW heating2 kW cooling370 kWh/yr | 5 | $118 | |
| Carrier 38QRG020N8/42QRG020N82.2 kW heating2 kW cooling378 kWh/yr | 5 | $121 | |
| Fujitsu AOTH07KNCA/ASTH07KNCA2.5 kW heating2 kW cooling427 kWh/yr | 4.5 | $137 |
Compare DXC07ZTLA-W/DXK07ZTLA-W with another model
Mitsubishi Heavy Industries DXC07ZTLA-W specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 2.00 kW
- Cooling power input
- 0.51 kW
- Rated heating capacity (7 Β°C)
- 2.70 kW
- Heating power input
- 0.64 kW
- EER, full load (tested)
- 4.03
- COP, full load (tested)
- 4.32
- Rated AEER
- 3.76
- Rated ACOP
- 4.08
- Standby power (PIA)
- 6.5 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 52 dB(A)
- Outdoor sound power
- 57 dB(A)
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- Thailand
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Mitsubishi Heavy Industries DXC07ZTLA-W zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 248 | 280 |
| Coldresidential | residential | 2.5 | 2.5 | 123 | 854 |
| Mixedcommercial | commercial | β | β | 309 | 153 |
| Mixedresidential | residential | 2.5 | 3.0 | 187 | 333 |
| Hotcommercial | commercial | β | β | 669 | 41 |
| Hotresidential | residential | 3.5 | 3.5 | 507 | 60 |
Part-load test points (20 values)
- h__h2_ext_cap_power_rated
- 1230 W
- c__t1_half_cap_power_rated
- 185 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 240 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 3200 W
- h__h1_half_cap_heat_cap_rated
- 1350 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_full_cap_power_rated
- 466.14000000000004 W
- c__low_temp_half_cap_power_rated
- 169.09 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 1000 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_full_cap_cooling_cap_rated
- 2154 W
- c__low_temp_half_cap_cooling_cap_rated
- 1077 W
Other model numbers on registration AAC7085
Registered together and sharing the same test results. Usually variants of the same unit.
Australian GEMS registration details
- Registration number
- AAC7085
- GEMS registration id
- 149968
- Status
- approved, available (self-reported)
- Registration expires
- 10 October 2027
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- SRK20/DXK07ZTLA-WF
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 8
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: mhiaa.com.au. How the derived figures are calculated.