Australia Β· costs in AUD
Reverse cycle split system air conditioner, wall hung
Mitsubishi Heavy Industries DXC28ZRA-W / DXK28ZRA-W Air Conditioner
Mitsubishi Heavy Industries DXC28ZRA-W / DXK28ZRA-W is a 8 kW reverse cycle split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC8718).
- Energy rating (cooling)
- 3
- Heating: 2.5
- Annual electricity use
- 1,821 kWh
- 678 cooling + 1,143 heating
- Estimated running cost
- $583 / year
- $49 / month Β· $5,827 over 10 years
- Capacity
- 8 kW cooling
- 9 kW heating
1% less electricity than the median of 125 comparable 8 kW reverse cycle split system registrations (1,834 kWh a year) in the mixed zone. Uses less than 53% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 54% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Mitsubishi Heavy Industries DXC28ZRA-W running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 3,577 | $1,145 | $11,446 |
| Mixed zone | 1,821 | $583 | $5,827 |
| Hot zone | 2,162 | $692 | $6,918 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 8 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Mdv C-UV-74N8-QC3W / CSV-72N8-QC7W7.7 kW heating7.2 kW cooling1,404 kWh/yr | 4 | $449 | |
| Panasonic U-71PZ4R5 / S-6071PU3E7.1 kW heating7.1 kW cooling1,426 kWh/yr | 3 | $456 | |
| Kogan KASSSAC71HD7.5 kW heating7.1 kW cooling1,433 kWh/yr | 4 | $459 | |
| Kogan KASSSAC71HE7.5 kW heating7.1 kW cooling1,433 kWh/yr | 4 | $459 | |
| Panasonic U-71PZ3R5 / S-6071PU3E7.1 kW heating7.1 kW cooling1,441 kWh/yr | 3 | $461 |
Air conditioners similar to the Mitsubishi Heavy Industries DXC28ZRA-W
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Haier 1U80QAFFRA / AS80QFFHRA9 kW heating8 kW cooling1,739 kWh/yr | 3.5 | $556 | |
| Kogan KASSSAC80HA8.2 kW heating8 kW cooling1,662 kWh/yr | 4 | $532 | |
| Carrier 38QHG080N8-1/42QHG080N8-18.2 kW heating8 kW cooling1,749 kWh/yr | 3 | $560 | |
| Actron Air WRC-080DS / WRE-080DS9 kW heating8 kW cooling1,749 kWh/yr | 3.5 | $560 | |
| Solar Acdc DGWA1-ACDCBLW-30KR29 kW heating8 kW cooling1,702 kWh/yr | 4 | $545 | |
| Kogan KASSSAC80H*8.2 kW heating8 kW cooling1,662 kWh/yr | 4 | $532 | |
| Midea MFEP80VA-W/MFEP80VA-N9 kW heating8 kW cooling1,748 kWh/yr | 4 | $559 | |
| Haier 1U80TPHRA / AS80TPHRA8.2 kW heating8 kW cooling1,669 kWh/yr | 3.5 | $534 |
Compare DXC28ZRA-W / DXK28ZRA-W with another model
Mitsubishi Heavy Industries DXC28ZRA-W specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 8.00 kW
- Cooling power input
- 2.22 kW
- Rated heating capacity (7 Β°C)
- 9.00 kW
- Heating power input
- 2.40 kW
- EER, full load (tested)
- 3.60
- COP, full load (tested)
- 3.77
- Rated AEER
- 3.59
- Rated ACOP
- 3.73
- Standby power (PIA)
- 3.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 58 dB(A)
- Outdoor sound power
- 68 dB(A)
- Demand response (AS/NZS 4755)
- Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
- Country of manufacture
- Thailand
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Mitsubishi Heavy Industries DXC28ZRA-W zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 930 | 981 |
| Coldresidential | residential | 3.5 | 2.0 | 425 | 3,152 |
| Mixedcommercial | commercial | β | β | 1,182 | 500 |
| Mixedresidential | residential | 3.0 | 2.5 | 678 | 1,143 |
| Hotcommercial | commercial | β | β | 2,671 | 102 |
| Hotresidential | residential | 3.5 | 3.0 | 2,001 | 161 |
Part-load test points (16 values)
- h__h2_ext_cap_power_rated
- 3010 W
- c__t1_half_cap_power_rated
- 735 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 835 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 8200 W
- h__h1_half_cap_heat_cap_rated
- 4500 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 4000 W
- c__low_temp_have_half_cap_results
- No
Other model numbers on registration AAC8718
Registered together and sharing the same test results. Usually variants of the same unit.
Australian GEMS registration details
- Registration number
- AAC8718
- GEMS registration id
- 166589
- Status
- approved, available (self-reported)
- Registration expires
- 31 March 2030
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- SRK/DXK_80/28_ZRA-W
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: mhiaa.com.au. How the derived figures are calculated.