Australia Β· costs in AUD
Reverse cycle multi-split / vrf air conditioner
Mitsubishi Heavy Industries FDC140KXZES1 Air Conditioner
Mitsubishi Heavy Industries FDC140KXZES1 is a 14 kW reverse cycle multi-split / vrf air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC9736).
- Energy rating (cooling)
- 2
- Heating: 2
- Annual electricity use
- 3,503 kWh
- 1,449 cooling + 2,054 heating
- Estimated running cost
- $1,121 / year
- $93 / month Β· $11,210 over 10 years
- Capacity
- 14 kW cooling
- 14 kW heating
2% more electricity than the median of 19 comparable 14 kW reverse cycle multi-split / vrf registrations (3,425 kWh a year) in the mixed zone. Uses less than 26% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 29% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Mitsubishi Heavy Industries FDC140KXZES1 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 6,331 | $2,026 | $20,259 |
| Mixed zone | 3,503 | $1,121 | $11,210 |
| Hot zone | 4,413 | $1,412 | $14,122 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 14 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RSUYA5AVM16 kW heating14 kW cooling2,817 kWh/yr | 3 | $901 | |
| Panasonic U-5LZ2E816 kW heating14 kW cooling2,845 kWh/yr | 3 | $910 | |
| Panasonic U-5LZ2E516 kW heating14 kW cooling2,845 kWh/yr | 3 | $910 | |
| Mitsubishi Electric PUMY-SP112YKMD3-A-BS14 kW heating12.5 kW cooling2,935 kWh/yr | 2.5 | $939 | |
| Mitsubishi Electric PUMY-SP112VKMD3-A14 kW heating12.5 kW cooling2,935 kWh/yr | 2.5 | $939 |
Air conditioners similar to the Mitsubishi Heavy Industries FDC140KXZES1
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Mitsubishi Electric PUMY-SP125VKMD3-A-BS16 kW heating14 kW cooling3,361 kWh/yr | 2.5 | $1,076 | |
| Panasonic U-5LZ2E516 kW heating14 kW cooling2,845 kWh/yr | 3 | $910 | |
| Mitsubishi Electric PUMY-SP125YKMD3-A Series16 kW heating14 kW cooling3,361 kWh/yr | 2.5 | $1,076 | |
| Braemar MCMX140D108B16 kW heating14 kW cooling4,533 kWh/yr | 1.5 | $1,451 | |
| Panasonic U-5LZ2E816 kW heating14 kW cooling2,845 kWh/yr | 3 | $910 | |
| Daikin RSUYA5AVM16 kW heating14 kW cooling2,817 kWh/yr | 3 | $901 |
Other Mitsubishi Heavy Industries models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Mitsubishi Heavy Industries FDC140KXZEN114 kW heating14 kW cooling3,546 kWh/yr | 2 | $1,135 | |
| Mitsubishi Heavy Industries FDC140KXZEN1-W14 kW heating14 kW cooling3,539 kWh/yr | 2 | $1,132 |
Compare FDC140KXZES1 with another model
Mitsubishi Heavy Industries FDC140KXZES1 specifications
- Type
- Reverse cycle
- Configuration
- Multi-split / VRF
- Air distribution
- Ducted or non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 14.00 kW
- Cooling power input
- 4.16 kW
- Rated heating capacity (7 Β°C)
- 14.00 kW
- Heating power input
- 3.86 kW
- EER, full load (tested)
- 3.30
- COP, full load (tested)
- 3.92
- Rated AEER
- 3.27
- Rated ACOP
- 3.52
- Standby power (PIA)
- 34.6 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R410A
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- 72 dB(A)
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- Thailand
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Mitsubishi Heavy Industries FDC140KXZES1 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,959 | 1,754 |
| Coldresidential | residential | 2.0 | 1.5 | 942 | 5,389 |
| Mixedcommercial | commercial | β | β | 2,453 | 940 |
| Mixedresidential | residential | 2.0 | 2.0 | 1,449 | 2,054 |
| Hotcommercial | commercial | β | β | 5,382 | 242 |
| Hotresidential | residential | 2.5 | 2.5 | 4,053 | 360 |
Part-load test points (16 values)
- h__h2_ext_cap_power_rated
- 4600 W
- c__t1_half_cap_power_rated
- 1500 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 1500 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 12500 W
- h__h1_half_cap_heat_cap_rated
- 7000 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 7000 W
- c__low_temp_have_half_cap_results
- No
Australian GEMS registration details
- Registration number
- AAC9736
- GEMS registration id
- 175910
- Status
- approved, available (self-reported)
- Registration expires
- 8 January 2031
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.4:2012
- MEPS
- 2019
- Product class
- Class 20
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: mhiaa.com.au. How the derived figures are calculated.