c/kWh
Energy rating (cooling)
3.5
Annual electricity use
565 kWh
Estimated running cost
$181 / year
$15 / month Β· $1,808 over 10 years
Capacity
7.1 kW cooling

4% less electricity than the median of 17 comparable 7 kW cooling only split system registrations (589 kWh a year) in the mixed zone. Uses less than 71% of them.

Across all 3,681 air conditioner registrations sold in Australia, it uses less than 91% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Mitsubishi Heavy Industries SRC24YRA-W running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 356$114$1,139
Mixed zone 565$181$1,808
Hot zone 1,654$529$5,293

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 7.1 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Gree GWC24ATEXF-K6DNA1E/O / GWC24ATEXF-K6DNA1E/I7.1 kW cooling522 kWh/yr4$167
Mitsubishi Electric MUY-GW71VFD2/MSY-GW71VFD27.1 kW cooling524 kWh/yr4$168
Mitsubishi Electric MUY-GW71VFD/MSY-GW71VFD27.1 kW cooling524 kWh/yr4$168

Air conditioners similar to the Mitsubishi Heavy Industries SRC24YRA-W

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Gree GWC24ATEXF-K6DNA1E/O / GWC24ATEXF-K6DNA1E/I7.1 kW cooling522 kWh/yr4$167
Panasonic CU-U71*KR / CS-U71*KR7.1 kW cooling629 kWh/yr3$201
Daikin RKM71WVMA / FTKM71WVMA7.1 kW cooling590 kWh/yr3$189
Panasonic CU-U71AKR / CS-U71AKR7.1 kW cooling629 kWh/yr3$201
Fujitsu AOTH24CNTA/ASTH24CNTA7.1 kW cooling610 kWh/yr3$195
Daikin RKM71W2VMA / FTKM71W2VMA7.1 kW cooling599 kWh/yr3$192
Mitsubishi Electric MUY-GW71VFD/MSY-GW71VFD7.1 kW cooling524 kWh/yr4$168
Mitsubishi Electric MUY-GW71VFD2/MSY-GW71VFD7.1 kW cooling524 kWh/yr4$168

Compare SRC24YRA-W/SRK24YRA-WF1 with another model

Mitsubishi Heavy Industries SRC24YRA-W specifications

Type
Cooling only
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
7.10 kW
Cooling power input
1.84 kW
Rated heating capacity (7 Β°C)
–
Heating power input
–
EER, full load (tested)
3.81
COP, full load (tested)
–
Rated AEER
3.83
Rated ACOP
–
Standby power (PIA)
3.6 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
55 dB(A)
Outdoor sound power
65 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Mitsubishi Heavy Industries SRC24YRA-W zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––734–
Coldresidential3.5–356–
Mixedcommercial––953–
Mixedresidential3.5–565–
Hotcommercial––2,170–
Hotresidential4.0–1,654–
Part-load test points (9 values)
c__t1_half_cap_power_rated
655 W
c__t1_have_min_cap_results
No
c__low_temp_full_cap_power_rated
1681.76 W
c__low_temp_half_cap_power_rated
565 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
3550 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_full_cap_cooling_cap_rated
7646.7 W
c__low_temp_half_cap_cooling_cap_rated
3820 W

Australian GEMS registration details

Registration number
AAC8232
GEMS registration id
161355
Status
approved, available (self-reported)
Registration expires
13 May 2029
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: mhiaa.com.au. How the derived figures are calculated.