Australia Β· costs in AUD
Reverse cycle split system air conditioner, wall hung
Mitsubishi Heavy Industries SRC50ZSXA-W/SRK50ZSXA-WF Air Conditioner
Mitsubishi Heavy Industries SRC50ZSXA-W/SRK50ZSXA-WF is a 5 kW reverse cycle split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC7736).
- Energy rating (cooling)
- 3.5
- Heating: 3
- Annual electricity use
- 1,093 kWh
- 402 cooling + 691 heating
- Estimated running cost
- $350 / year
- $29 / month Β· $3,498 over 10 years
- Capacity
- 5 kW cooling
- 6 kW heating
About the same electricity as the median of 240 comparable 5 kW reverse cycle split system registrations (1,093 kWh a year) in the mixed zone. Uses less than 49% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 75% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Mitsubishi Heavy Industries SRC50ZSXA-W running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 2,121 | $679 | $6,787 |
| Mixed zone | 1,093 | $350 | $3,498 |
| Hot zone | 1,281 | $410 | $4,099 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 5 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling839 kWh/yr | 4 | $268 | |
| Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling847 kWh/yr | 4 | $271 | |
| Actron Air WRC-050CS / WRE-050CS5 kW heating5 kW cooling942 kWh/yr | 4.5 | $301 | |
| Panasonic CU-HZ50DKR / CS-HZ50DKR6 kW heating5 kW cooling949 kWh/yr | 5 | $304 | |
| Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling949 kWh/yr | 4 | $304 |
Air conditioners similar to the Mitsubishi Heavy Industries SRC50ZSXA-W
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Rinnai HONRPX50/HINRPX50M6 kW heating5 kW cooling997 kWh/yr | 5 | $319 | |
| Haier 1U50PFHRA / AS50PFHRA5.3 kW heating5 kW cooling990 kWh/yr | 4 | $317 | |
| Daikin RXM50WVMA / FTXM50WVMA6 kW heating5 kW cooling942 kWh/yr | 5 | $301 | |
| Midea MFEP51VA-W/MFEP51VA-N5.3 kW heating5 kW cooling1,008 kWh/yr | 4 | $323 | |
| Actron Air WRC-050CS / WRE-050CS5 kW heating5 kW cooling942 kWh/yr | 4.5 | $301 | |
| Midea MFEZ50VA-W/MFEZ50VA-N6 kW heating5 kW cooling997 kWh/yr | 5 | $319 | |
| Daikin RXM50AVMA / FTXM50AVMA6 kW heating5 kW cooling937 kWh/yr | 5 | $300 | |
| Panasonic CU-HZ50DKR / CS-HZ50DKR6 kW heating5 kW cooling949 kWh/yr | 5 | $304 |
Compare SRC50ZSXA-W/SRK50ZSXA-WF with another model
Mitsubishi Heavy Industries SRC50ZSXA-W specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 5.00 kW
- Cooling power input
- 1.24 kW
- Rated heating capacity (7 Β°C)
- 6.00 kW
- Heating power input
- 1.36 kW
- EER, full load (tested)
- 4.05
- COP, full load (tested)
- 4.44
- Rated AEER
- 4.00
- Rated ACOP
- 4.38
- Standby power (PIA)
- 3.1 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 59 dB(A)
- Outdoor sound power
- 63 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- Thailand
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Mitsubishi Heavy Industries SRC50ZSXA-W zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 560 | 594 |
| Coldresidential | residential | 3.5 | 2.5 | 256 | 1,865 |
| Mixedcommercial | commercial | β | β | 706 | 308 |
| Mixedresidential | residential | 3.5 | 3.0 | 402 | 691 |
| Hotcommercial | commercial | β | β | 1,577 | 66 |
| Hotresidential | residential | 4.0 | 3.5 | 1,178 | 103 |
Part-load test points (20 values)
- h__h2_ext_cap_power_rated
- 2070 W
- c__t1_half_cap_power_rated
- 445 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 520 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 6000 W
- h__h1_half_cap_heat_cap_rated
- 3000 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_full_cap_power_rated
- 1133.3600000000001 W
- c__low_temp_half_cap_power_rated
- 406.73 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 2500 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_full_cap_cooling_cap_rated
- 5385 W
- c__low_temp_half_cap_cooling_cap_rated
- 2692.5 W
Australian GEMS registration details
- Registration number
- AAC7736
- GEMS registration id
- 156143
- Status
- approved, available (self-reported)
- Registration expires
- 27 August 2028
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: mhiaa.com.au. How the derived figures are calculated.