c/kWh
Energy rating (cooling)
2.5
Heating: 2
Annual electricity use
2,342 kWh
939 cooling + 1,403 heating
Estimated running cost
$749 / year
$62 / month Β· $7,494 over 10 years
Capacity
9.5 kW cooling
10 kW heating

4% less electricity than the median of 128 comparable 10 kW reverse cycle ducted split system registrations (2,433 kWh a year) in the mixed zone. Uses less than 72% of them.

Across all 3,638 air conditioner registrations sold in Australia, it uses less than 46% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Panasonic U-100PZ4R5 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,364$1,396$13,965
Mixed zone 2,342$749$7,494
Hot zone 2,912$932$9,318

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 9.5 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Fujitsu AOTH30KCTA/ARTH30KMTAP10 kW heating8.5 kW cooling0 kWh/yr–$0
Fujitsu AOTH30KBTA/ARTH30KMTAP10 kW heating8.5 kW cooling0 kWh/yr–$0
Panasonic U-100PZ4R8 / S-100PE4R10 kW heating10 kW cooling1,449 kWh/yr2.5$464
Panasonic U-100PZ4R8 / S-100PE4RN10 kW heating10 kW cooling1,449 kWh/yr2.5$464
Brivis AONSR13B1/AINHU11B111.3 kW heating10.3 kW cooling1,881 kWh/yr4.5$602

Air conditioners similar to the Panasonic U-100PZ4R5

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
LG UU100WR2 U30/UMN100M2 N2010.8 kW heating9.5 kW cooling2,999 kWh/yr2$960
LG UU100WR3 U30/UMN100M2 N2010.8 kW heating9.5 kW cooling2,350 kWh/yr2.5$752
Midea UCMI105OB/DUCMI105IHB11 kW heating10 kW cooling2,120 kWh/yr4$678
Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling1,884 kWh/yr3.5$603
Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling1,936 kWh/yr3.5$620
Carrier 38QSP090N8/42QSP090N810.5 kW heating9 kW cooling1,976 kWh/yr3.5$632

Other Panasonic models of similar capacity

ModelStarsEst. cost / yrCompare
Panasonic U-100PZH3R8/S-1014PF3E10.8 kW heating9.5 kW cooling2,017 kWh/yr3.5$645
Panasonic U-100PZ4R5 / S-1014PF3E9.5 kW heating9.5 kW cooling2,011 kWh/yr3$644

Compare U-100PZ4R5 / S-100PE4RN with another model

Panasonic U-100PZ4R5 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
9.50 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
10.00 kW
Heating power input
–
EER, full load (tested)
3.22
COP, full load (tested)
3.59
Rated AEER
3.11
Rated ACOP
3.51
Standby power (PIA)
15.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-100PZ4R5 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,2091,163
Coldresidential2.52.06013,763
Mixedcommercial––1,546604
Mixedresidential2.52.09391,403
Hotcommercial––3,532141
Hotresidential3.03.02,696216
Part-load test points (22 values)
h__h1_min_cap_power_rated
540 W
h__h2_ext_cap_power_rated
3150 W
c__t1_half_cap_power_rated
1060 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1100 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2700 W
h__h2_ext_cap_heat_cap_rated
8800 W
h__h1_half_cap_heat_cap_rated
5000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
510 W
c__low_temp_half_cap_power_rated
900 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
4750 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3050 W
c__low_temp_half_cap_cooling_cap_rated
5000 W

Other model numbers on registration AAC9154

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC9154
GEMS registration id
–
Status
approved
Registration expires
31 July 2030
Registered for sale in
Australia, New Zealand
Family
U-100PZ4R5 / S-100PE4*
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
10

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.