Australia Β· costs in AUD

Reverse cycle split system air conditioner
Panasonic U-100PZH3R5/S-1014PF3E Air Conditioner
Panasonic U-100PZH3R5/S-1014PF3E is a 9.5 kW reverse cycle ducted split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC9623).
- Energy rating (cooling)
- 3.5
- Heating: 3
- Annual electricity use
- 2,017 kWh
- 730 cooling + 1,287 heating
- Estimated running cost
- $645 / year
- $54 / month Β· $6,454 over 10 years
- Capacity
- 9.5 kW cooling
- 10.8 kW heating
17% less electricity than the median of 129 comparable 10 kW reverse cycle ducted split system registrations (2,429 kWh a year) in the mixed zone. Uses less than 93% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 50% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Panasonic U-100PZH3R5 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 3,848 | $1,231 | $12,314 |
| Mixed zone | 2,017 | $645 | $6,454 |
| Hot zone | 2,262 | $724 | $7,238 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 9.5 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-100PZ4R8 / S-100PE4*10 kW heating10 kW cooling1,449 kWh/yr | 2.5 | $464 | |
| Panasonic U-100PZ4R8 / S-100PE4RN10 kW heating10 kW cooling1,449 kWh/yr | 2.5 | $464 | |
| Brivis AONSR13B1/AINHU11B111.3 kW heating10.3 kW cooling1,881 kWh/yr | 4.5 | $602 | |
| Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling1,884 kWh/yr | 3.5 | $603 | |
| Carrier 38QSM090D8S/42QSM090D8S9.3 kW heating8.7 kW cooling1,923 kWh/yr | 3.5 | $615 |
Air conditioners similar to the Panasonic U-100PZH3R5
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| LG UU100WR3 U30/UMN100M2 N2010.8 kW heating9.5 kW cooling2,350 kWh/yr | 2.5 | $752 | |
| LG UU100WR2 U30/UMN100M2 N2010.8 kW heating9.5 kW cooling2,999 kWh/yr | 2 | $960 | |
| Midea UCMI105OB/DUCMI105IHB11 kW heating10 kW cooling2,120 kWh/yr | 4 | $678 | |
| Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling1,936 kWh/yr | 3.5 | $620 | |
| Carrier 38QSP090N8/42QSP090N810.5 kW heating9 kW cooling1,976 kWh/yr | 3.5 | $632 | |
| Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling1,884 kWh/yr | 3.5 | $603 |
Other Panasonic models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-100PZ4R5 / S-1014PF3E9.5 kW heating9.5 kW cooling2,011 kWh/yr | 3 | $644 | |
| Panasonic U-100PZH3R8/S-1014PF3E10.8 kW heating9.5 kW cooling2,017 kWh/yr | 3.5 | $645 |
Compare U-100PZH3R5/S-1014PF3E with another model
Panasonic U-100PZH3R5 specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 9.50 kW
- Cooling power input
- 2.28 kW
- Rated heating capacity (7 Β°C)
- 10.80 kW
- Heating power input
- 2.72 kW
- EER, full load (tested)
- 4.35
- COP, full load (tested)
- 4.18
- Rated AEER
- 4.08
- Rated ACOP
- 3.90
- Standby power (PIA)
- 15.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
- Dimensions (WΓHΓD)
- 1400 Γ 290 Γ 700 mm
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Panasonic U-100PZH3R5 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 923 | 1,054 |
| Coldresidential | residential | 3.5 | 2.5 | 471 | 3,377 |
| Mixedcommercial | commercial | β | β | 1,181 | 558 |
| Mixedresidential | residential | 3.5 | 3.0 | 730 | 1,287 |
| Hotcommercial | commercial | β | β | 2,674 | 131 |
| Hotresidential | residential | 4.0 | 4.0 | 2,062 | 200 |
Part-load test points (22 values)
- h__h1_min_cap_power_rated
- 545 W
- h__h2_ext_cap_power_rated
- 4140 W
- c__t1_half_cap_power_rated
- 870 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 970 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 3200 W
- h__h2_ext_cap_heat_cap_rated
- 12000 W
- h__h1_half_cap_heat_cap_rated
- 5400 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 440 W
- c__low_temp_half_cap_power_rated
- 715 W
- c__low_temp_have_min_cap_results
- Yes
- c__t1_half_cap_cooling_cap_rated
- 4750 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 3550 W
- c__low_temp_half_cap_cooling_cap_rated
- 5100 W
Australian GEMS registration details
- Registration number
- AAC9623
- GEMS registration id
- 174369
- Status
- approved, available (self-reported)
- Registration expires
- 8 December 2030
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 10
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.