c/kWh
Energy rating (cooling)
3.5
Heating: 3
Annual electricity use
2,017 kWh
730 cooling + 1,287 heating
Estimated running cost
$645 / year
$54 / month Β· $6,454 over 10 years
Capacity
9.5 kW cooling
10.8 kW heating

17% less electricity than the median of 129 comparable 10 kW reverse cycle ducted split system registrations (2,429 kWh a year) in the mixed zone. Uses less than 93% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 50% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Panasonic U-100PZH3R5 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,848$1,231$12,314
Mixed zone 2,017$645$6,454
Hot zone 2,262$724$7,238

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 9.5 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Panasonic U-100PZ4R8 / S-100PE4*10 kW heating10 kW cooling1,449 kWh/yr2.5$464
Panasonic U-100PZ4R8 / S-100PE4RN10 kW heating10 kW cooling1,449 kWh/yr2.5$464
Brivis AONSR13B1/AINHU11B111.3 kW heating10.3 kW cooling1,881 kWh/yr4.5$602
Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling1,884 kWh/yr3.5$603
Carrier 38QSM090D8S/42QSM090D8S9.3 kW heating8.7 kW cooling1,923 kWh/yr3.5$615

Air conditioners similar to the Panasonic U-100PZH3R5

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
LG UU100WR3 U30/UMN100M2 N2010.8 kW heating9.5 kW cooling2,350 kWh/yr2.5$752
LG UU100WR2 U30/UMN100M2 N2010.8 kW heating9.5 kW cooling2,999 kWh/yr2$960
Midea UCMI105OB/DUCMI105IHB11 kW heating10 kW cooling2,120 kWh/yr4$678
Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling1,936 kWh/yr3.5$620
Carrier 38QSP090N8/42QSP090N810.5 kW heating9 kW cooling1,976 kWh/yr3.5$632
Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling1,884 kWh/yr3.5$603

Other Panasonic models of similar capacity

ModelStarsEst. cost / yrCompare
Panasonic U-100PZ4R5 / S-1014PF3E9.5 kW heating9.5 kW cooling2,011 kWh/yr3$644
Panasonic U-100PZH3R8/S-1014PF3E10.8 kW heating9.5 kW cooling2,017 kWh/yr3.5$645

Compare U-100PZH3R5/S-1014PF3E with another model

Panasonic U-100PZH3R5 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
9.50 kW
Cooling power input
2.28 kW
Rated heating capacity (7 Β°C)
10.80 kW
Heating power input
2.72 kW
EER, full load (tested)
4.35
COP, full load (tested)
4.18
Rated AEER
4.08
Rated ACOP
3.90
Standby power (PIA)
15.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Dimensions (WΓ—HΓ—D)
1400 Γ— 290 Γ— 700 mm
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-100PZH3R5 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––9231,054
Coldresidential3.52.54713,377
Mixedcommercial––1,181558
Mixedresidential3.53.07301,287
Hotcommercial––2,674131
Hotresidential4.04.02,062200
Part-load test points (22 values)
h__h1_min_cap_power_rated
545 W
h__h2_ext_cap_power_rated
4140 W
c__t1_half_cap_power_rated
870 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
970 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3200 W
h__h2_ext_cap_heat_cap_rated
12000 W
h__h1_half_cap_heat_cap_rated
5400 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
440 W
c__low_temp_half_cap_power_rated
715 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
4750 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3550 W
c__low_temp_half_cap_cooling_cap_rated
5100 W

Australian GEMS registration details

Registration number
AAC9623
GEMS registration id
174369
Status
approved, available (self-reported)
Registration expires
8 December 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 10

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.